Ureteral metal stents: a tale or a tool?

نویسندگان

  • Evangelos N Liatsikos
  • George C Kagadis
  • George A Barbalias
  • Dimitrios Siablis
چکیده

There are four types of ureteral metal stents: self expandable, balloon expandable, covered, and thermoexpandable shape-memory. Insertion of metal stents requires expertise with transurethral and percutaneous techniques. The stricture is traversed with the aid of a guidewire via a percutaneous nephrostomy, and the stenotic segment is dilated using a high-pressure balloon catheter. The stent is then inserted over the guidewire, such that the upper end bypasses the obstruction by at least 3 to 4 cm, while the lower end extends intravesically for 0.5 to 1 cm from the ureteral orifice. If necessary, two or more stents are placed in sequence, overlapping by at least 2 to 3 cm. Metal stents were initially used for the relief of end-stage malignant disease, and their role in the treatment of benign ureteral strictures is still undefined. Patients often complain of abdominal discomfort and mild pain after stent insertion, which soon resolve spontaneously. Hematuria usually stops after a few days and does not necessitate any treatment. Mild urothelial hyperplasia in the stent lumen is common but usually regresses after 4 to 6 weeks. Many authors suggest the use of a double-pigtail catheter for the first 4 to 6 weeks to avoid narrowing of the ureteral lumen. The influence of stents on ureteral peristalsis is a major but poorly documented issue. Encrustation is a significant problem that needs to be addressed. The characteristics of both the patient and the stent influence its likelihood. Migration of coated metal stents was seen in 81% of patients at our center. Virtual endoscopy has recently been introduced as a tool for the follow-up of patients with stented ureters. Further design development is necessary to obtain the ideal ureteral metal stent. In a recent study in female pigs, paclitaxel-eluting metal stents engendered less inflammation and hyperplasia of the surrounding tissues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ureteral metal stents: 10-year experience with malignant ureteral obstruction treatment.

PURPOSE Ureteral patency in malignant ureteral obstruction cases is a therapeutic challenge. We report our long-term experience with palliative treatment for extrinsic malignant ureteral obstruction with percutaneous placement of metal mesh stents. MATERIALS AND METHODS From January 1996 to December 2005, 90 patients with a mean age of 59 years (range 35 to 80) with ureteral obstruction due t...

متن کامل

Stents for malignant ureteral obstruction

Malignant ureteral obstruction can result in renal dysfunction or urosepsis and can limit the physician's ability to treat the underlying cancer. There are multiple methods to deal with ureteral obstruction including regular polymeric double J stents (DJS), tandem DJS, nephrostomy tubes, and then more specialized products such as solid metal stents (e.g., Resonance Stent, Cook Medical) and poly...

متن کامل

Ureteral stents are part of an ever-expanding technology horizon

Transl Androl Urol 2014;3(3):320 www.amepc.org/tau Although the concept of ureteral stenting has been around since the 1800s, it was not until the 1960s that the more modern version ureteral stents (at that time referred to as splints) were placed endoscopically. Many of the common problems with ureteral stents (irritative voiding symptoms, hematuria, encrustation, bacterial colonization, etc.)...

متن کامل

Malignant Ureteral Obstruction: Functional Duration of Metallic versus Polymeric Ureteral Stents

BACKGROUND Ureteral obstruction caused by extrinsic compression is often associated with intra-abdominal cancers. Internal drainage with ureteral stents is typically the first-line therapy to relieve such obstructions. Novel designs of ureteral stents made of different materials have been invented to achieve better drainage. In this study, we described the functional outcomes of a Resonance met...

متن کامل

Application of paclitaxel-eluting metal mesh stents within the pig ureter: an experimental study.

OBJECTIVE The purpose of the present study is to compare the standard bare metal stents (BMS) with the Paclitaxel-Drug Eluting Stent (DES) in the ureter of a pig model. MATERIALS AND METHODS We report on an experimental study with ten female pigs weighing between 25 and 30 kg. The stents were randomly placed in either the right or left ureter in each of 10 study animals, for a total of 20 ste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endourology

دوره 19 8  شماره 

صفحات  -

تاریخ انتشار 2005