Point-of-Care Measurements of HbA1c: Simplicity Does Not Mean Laxity With Controls
نویسندگان
چکیده
Point-of-care HbA1c measurements (POC-A1Cs) have been adopted by many diabetes clinics to improve the quality of care provided to their patients (1). Herein, we show that reliability of this approach might be questioned. POC-A1Cs routinely used in the ambulatory section of our diabetes clinic was evaluated on 100 diabetic patients (type 1, n 5 58; type 2, n 5 42) attending the clinic from 1 October 2011 to 30 November 2011. Patients with abnormal hemoglobin traits or shortened erythrocyte life span were excluded. Blood-capillary samples were analyzed by POC-A1C (DCA Vantage; Siemens Medical Solutions Diagnostics, Cergy-Pontoise, France) and venous EDTA-anticoagulated blood specimens by the central laboratory high-performance liquid chromatography measurement (Tosoh HLC-723 GHb G8; BioSciences, Lyon, France). Both methods were certified (NGSP/ Diabetes Control and Complications Trial [DCCT] and International Federation of Clinical Chemistry and Laboratory Medicine [IFCC]). Internal quality evaluation showed CVs consistently below 3%. HbA1c values obtained from POCA1C were found to be below those given by the central laboratory in 98% of the cases. POC-A1C values differed by a mean of20.506 0.28%. Central laboratory and the POC-A1C values were correlated, but the regression equation suggested a slight proportional bias (slope: 0.87) and a greater constant bias (intercept with y-axis: 0.37%). BlandAltman statistics showed a significant correlation between the delta and the mean of HbA1c. The higher the HbA1c value was, the greater the discrepancy between both methods. To evaluate whether these discrepancies in HbA1c values can interfere with decision making, we assessed the possible POC-A1C–induced errors in categorization at the different HbA1c threshold levels used by the clinicians to modify hypoglycemic treatment. If the therapeutic HbA1c objective was#6.5%, then 11% of the population was incorrectly considered in the target by POC-A1C. This proportion of misclassification increased to 24% when the therapeutic target was #7% and decreased thereafter (#7.5%, 12%; #8.0%, 8%). The higher misclassification rate observed for a 7% threshold is due to the fact that the proportion of patients around this value is especially high in our unselected cohort (HbA1c median: 7.28%). This real-life analysis differed from bench tests, which are usually performed to validate POC-A1Cmethods (2). Similar tendencies to an underevaluation of HbA1c by POC methods have been noted already by Holmes et al. (3) and by Twomey et al. (4) in the context of the U.K. “pay-for-performance program.” At the time of the current study, no sign of a possible drift in HbA1c determination was given by external quality-control procedures. One cannot minimize the clinical relevance of this transitory drift observed with the POC-A1C device. The solution for maintaining routine POC-A1C use involves every participant in the chain. First, lot-to-lot stability must be improved and controlled by the manufacturer as already suggested by Little et al. (5). External quality-control procedures should be more frequent and reactive. Clinicians should be aware of any discrepancies between POC-A1C and central laboratory values and, if necessary, carry out a local audit as we did. Finally, it should be dangerous to rely only upon POC-A1C to evaluate the quality of long-term glucose control in diabetic patients. Measurement of HbA1c by laboratory method should be performed at least once a year.
منابع مشابه
Implementation of "Chronic Care Model" for Diabetes Care in Iranian Primary Health Care: Does it work?
Objective: Traditional health care systems were not capable to face successfully with chronic diseases including diabetes mellitus. In this regard, the Chronic Care Model or CCM was created to promote quality of care. The aim of this study was to examine whether establishment of chronic care model, with focus on diabetic patients, has led to clinically significant outcomes in Iran. Materials a...
متن کاملبررسی سطح سرمی فاکتور رشد شبه انسولین نوع یک (IGF-I) و لپتین در بیماران دیابتی و مقایسه آن با افراد سالم
Background: Diabetes is a common endocrine disease in human kind. In most type II diabetic patients, obesity and overweight status account as the serious health problems worldwide and variety of endocrine factors well known that have regulatory role in weight balance and body composition including Leptin and IGF-I factor. The aim of this study was to examine the correlation between Leptin and I...
متن کاملمعرفی آزمایش HbA1c به منظور تشخیص، ارزیابی و کنترل دراز مدت دیابت در بیماران مبتلا به پریودنتیت
Regard this, that majority of Diabetic patients that soffer from periodontal disease. Now, most of espesialist belive that these patients need to control their diabets with new methods for decreasing and controlling thier periodontal disease.Today, most of physician, majority of periodontal for controlling of HbAlc Test.This test does not need to patient's cooperation and can do in any time.Thi...
متن کاملAnalysis of office-based glycohemoglobin measurement.
Hemoglobin A1c (HbA1c) measurements are important for monitoring glycemic control in patients with diabetes. The positive impact of point-of-care HbA1c measurements on patient management is described in the literature. The general analytical requirements for HbA1c testing are described. The analytical evaluation of a new point-of-care HbA1c analyzer, suitable for a physician's office, against t...
متن کاملDoes anthropometric measurements correlate with hematological parameters after the adolescent growth period?
Introduction: Musculoskeletal growth is variable during adolescent period and reaches its maximum by 18 years, whereas hemopoietic parameters reach adult values by 15 years. After adolescence period, the blood parameters may vary with nutrition and built of the individual. The purpose of this study was to find out any correlation between anthropometric and hematological parameters after the ado...
متن کامل