In Vivo 3D Imaging of Human Lateral Geniculate Nucleus using Optimized Inversion Recovery Sequence at 3T and 7T

نویسندگان

  • C. Moon
  • J-H. Kim
  • J. Wang
  • K. T. Bae
چکیده

[Introduction] Lateral geniculate nucleus (LGN) functions as a thalamic relay station in the projection of visual pathway from retinal ganglion cells to the primary visual cortex. A recent MR imaging study of human LGN in vivo demonstrated that the height of LGN is smaller in glaucoma patients than normal (those without glaucoma) subjects [1]. This study implies that morphometry of LGN is an important potential biomarker for the neurodegenerative glaucoma disease. However, precise delineation of LGN anatomy in 3D using MR image is technically challenging because of the LGN’s location deep in the brain, small size (diameter 4 – 6 mm), and tissue signal similar to the surrounding white matters, such as optic radiation (OR). In this study, we demonstrated a significant improvement in the tissue contrast of LGN by a using magnetization-preparation-rapid-acquisitiongradient-echo (MPRAGE) sequence with optimized inversion time (TI) at 3T and 7T. [Methods and materials] All scans were performed on a 3T and 7T scanner (Siemens Medical Solutions, Erlangen, Germany) with single-loop surface coils for imaging ex vivo brain specimen, and 32-/9-channel RF head coils for imaging LGN in vivo. MR imaging of the brain specimen was performed at 3T to assess the degree of LGN tissue contrast improvement with inversion-recovery (IR) vs. proton-density (PD) imaging in 2D, which is known to produce the best LGN tissue contrast among conventional MR sequences. The specimen was also scanned at 7T to image the LGN using 3D MPRAGE. MR imaging of LGN in vivo was performed at 3T and 7T with two normal, healthy volunteers (28, 40 yrs). A series of IR gradient-echo (GRE) images were obtained by varying TI’s. Tissue signal intensity and contrast was measured by placing ROIs over the OR, LGN, thalamus, and internal capsule and was then plotted against TI. The image intensity (y) vs. inversion time (t) was fitted using y = a·{1-2·exp(-b·t)}. We determined the TI that maximized the relative contrast of LGN (L) to other tissues (C) which was defined by |C-L|/|C+L|. Then, the relative contrast of LGN was compared between PD turbo-spin-echo (TSE) and IR-GRE image with the optimal TI at 3T. In addition, the proposed LGN imaging method was compared with conventional GRE and MPRAGE imaging with CSF suppression at 7T. Finally, LGN was segmented from the proposed MPRAGE images and the volume of LGN was measured. [Results and conclusions] Substantial changes in tissue signal intensity with varying TI’s were detected on IR-GRE images of ex vivo specimen (Figs. 1A and B). The relative contrast of LGN was maximized at TI = ~120 ms at 3T because the greatest suppression of signal intensity in OR was at this value. The relative contrast of LGN was higher on the IR-GRE images than PD-TSE image: 64.5% vs. 30.5%, and 50.0% vs. 22.3% at two different slices (Figs. 1C – F). The IR imaging of LGN in vivo vs. PD-TSE imaging revealed the same trend (data not shown). High-resolution images of the ex vivo mid-brain obtained using 3D MPRAGE sequence with TI = ~200 ms at 7T are shown in Fig. 2. Sub-nuclei of thalamus, lateral and medial geniculate nuclei, and hippocampus were clearly discernible. In comparison, in vivo LGN was not easily distinguishable from the surrounding structures on conventional GRE or MPRAGE with CSF suppression images (white-arrowheads in Figs. 3A & B), even at high-resolution (~130 μm to ~500 μm/pixel). The TI for the highest contrast in MPRAGE imaging of LGN in vivo was ~450 ms (3T) and ~550 ms (7T). At these TI’s, LGN was sharply demarcated from OR (Figs. 3C & D). The SNR of LGN in the MPRAGE images at 7T was superior to that at 3T: ~30 vs. ~18. The segmented and measured volumes of LGN were 120.5 143 mm from the 7T MPRAGE images which were within the reported 91.1 – 157 mm measured from ex vivo specimens [4]. Volumes of LGN were not measured from the 3T images because the boundary of LGN was not clearly defined (noisy pixels). In conclusion, excellent tissue contrast of LGN and suppression of the surrounding OR tissue signal were achieved using a 3D MPRAGE sequence with appropriate TI. This sequence was superior to other sequences commonly used for LGN imaging including PD, GRE, and typical MPRAGE. MR imaging of LGN at 7T was superior to 3T with doubling of SNR at 7T. An imaging method that allows accurate and reliable volume measurement of LGN is crucial for the investigation of the association between LGN atrophy in vivo and neurodegenerative glaucoma. [Reference] 1. Gupta et al., Br J Ophthal, 93:56-60 (2009). 2. Wright et al., Magn Res Mater Phy, 21:121-130 (2008). 3. Deichmann et al., Neuroimage, 12:112-127 (2000). 4. Andrews et al., JNS, 17:2859-2868 (2000). Fig. 1 Ex vivo specimen LGN imaging at 3T. (A) IRGRE w/ different TIs, (B) Time-plot, (C & D) IR-GRE with TI 150 ms, and (E & F) PDTSE images; 1) 2D IR-GRE; TR/TE/TI 4000/5.04/(70 – 800) ms and 2) PD-TSE; TR/TE 4500/15 ms. Fig. 2 Ex vivo highresolution LGN MPRAGE image at 7T. The imaging parameters are TR/TE/TI 2000/3.59/200 ms, and isotropic resolution 0.3 mm. Sagittal, coronal, and axial view in clock-wise rotation. Abbreviations; A – anterior, D – dorsal, and R – right.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-high-field MR imaging in polymicrogyria and epilepsy.

BACKGROUND AND PURPOSE Polymicrogyria is a malformation of cortical development that is often identified in children with epilepsy or delayed development. We investigated in vivo the potential of 7T imaging in characterizing polymicrogyria to determine whether additional features could be identified. MATERIALS AND METHODS Ten adult patients with polymicrogyria previously diagnosed by using 3T...

متن کامل

Visualization of the Medial and Lateral Geniculate Nucleus on Phase Difference Enhanced Imaging.

BACKGROUND AND PURPOSE The precise identification and measurement of the medial geniculate nucleus and lateral geniculate nucleus on MR imaging remain technically challenging because the thalamic nuclei are small structures. We compared the visualization of the medial geniculate nucleus and lateral geniculate nucleus on phase difference enhanced imaging with 3D high-resolution phase imaging, 2D...

متن کامل

A comparison of 3T and 7T in the detection of small parenchymal veins within MS lesions.

OBJECTIVE Histologic examination of multiple sclerosis (MS) brain lesions reveals heterogeneity including the presence or absence of a central blood vessel. Recent work has shown that T2* weighted magnetic resonance imaging at 7T allows the identification of small parenchymal veins within MS lesions. The aims of this study were (1) to compare whether a comparable sequence at 3T was also capable...

متن کامل

Histological and Biochemical Alterations in the Superior Colliculus and Lateral Geniculate Nucleus of Juvenile Rats Following Prenatal Exposure to Marijuana Smoke

Prenatal exposure to marijuana has been associated with a variety of brain deficits, as Δ9-tetrahydrocannabinol (THC), its main active ingredient crosses the placenta and affects foetal brain development. Despite this effect, marijuana remains a commonly abused substance among pregnant women. In the current study, we examined the histological and biochemical changes in the superior colliculus (...

متن کامل

Saturation recovery allows T1 mapping in the human heart at 7T with a commercial MRI scanner

Background Myocardial T1 mapping at 1.5T and 3T distinguishes powerfully between normal and diseased tissue with focal and diffuse pathology. We recently reported the first human myocardial T1s at 7T using the ShMOLLI +IE inversion recovery sequence. Yet even using a unique 7T scanner with 16kW RF output, perfect magnetization inversion was impossible. We now introduce a saturation recovery met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009