The Effect of Motion Correction on Pharmacokinetic Parameter Estimation

نویسندگان

  • Andrew Melbourne
  • John H. Hipwell
  • David J. Hawkes
چکیده

A dynamic-contrast-enhanced magnetic resonance imaging (DCE-MRI) dataset consists of many imaging frames, often acquired both before and after contrast injection. Due to the length of time spent acquiring images, patient motion is likely and image re-alignment or registration is required before further analysis such as pharmacokinetic model fitting. Non-rigid image registration procedures may be used to correct motion artefacts; however, a careful choice of registration strategy is required to reduce misregistration artefacts associated with enhancing features. This work investigates the effect of registration on the results of model-fitting algorithms for 52 DCE-MR mammography cases for 14 patients. Results are divided into two sections: a comparison of registration strategies in which a DCE-MRI-specific algorithm is preferred in 50% of cases, followed by an investigation of parameter changes with known applied deformations, inspecting the effect of magnitude and timing of motion artefacts. Increased motion magnitude correlates with increased model-fit residual and is seen to have a strong influence on the visibility of strongly enhancing features. Motion artefacts in images close to the contrast agent arrival have a disproportionate effect on discrepancies in parameter estimation. The choice of algorithm, magnitude of motion and timing of the motion are each shown to influence estimated pharmacokinetic parameters even when motion magnitude is small.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

Comparison of the effect of a course of posture correction and strength exercises with emphasis on head and neck position on pain, neck muscle weakness and range of motion in inactive men with chronic neck pain.

Background and Objectives: In the last two decades, the prevalence of neck pain has been increasing and now it is considered the second musculoskeletal disorder after back pain. The general purpose of this research is to compare the effect of a course of posture correction and strength exercises with emphasis on the head and neck position on Pain, weakness of neck muscles and range of motion of...

متن کامل

Preventing Signal Degradation During Elastic Matching of Noisy DCE-MR Eye Images

Motion during the acquisition of dynamic contrast enhanced MRI can cause model-fitting errors requiring co-registration. Clinical implementations use a pharmacokinetic model to determine lesion parameters from the contrast passage. The input to the model is the time-intensity plot from a region of interest (ROI) covering the lesion extent. Motion correction meanwhile involves interpolation and ...

متن کامل

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

Evaluation and Comparison of Topographic Correction Models Is Applied on the Series Landsat Images Using Spectrometery Data

The effect of topography on the radiance record in satellite image, probably reduce the accuracy of algorithem impliementation on the images . Therefore, to reduce the effect of topography, various correction models based on interaction between light and object needs to be defined. This research introduces lombertin correction model (Cosine model) and non_lombertin correction model (mineart and...