A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo.
نویسندگان
چکیده
BACKGROUND AND PURPOSE A challenge with the T1-weighted postcontrast Cartesian spin-echo and turbo spin-echo brain MR imaging is the presence of flow artifacts. Our aim was to develop a rapid 2D spiral spin-echo sequence for T1-weighted MR imaging with minimal flow artifacts and to compare it with a conventional Cartesian 2D turbo spin-echo sequence. MATERIALS AND METHODS T1-weighted brain imaging was performed in 24 pediatric patients. After the administration of intravenous gadolinium contrast agent, a reference Cartesian TSE sequence with a scanning time of 2 minutes 30 seconds was performed, followed by the proposed spiral spin-echo sequence with a scanning time of 1 minutes 18 seconds, with similar spatial resolution and volumetric coverage. The results were reviewed independently and blindly by 3 neuroradiologists. Scores from a 3-point scale were assigned in 3 categories: flow artifact reduction, subjective preference, and lesion conspicuity, if any. The Wilcoxon signed rank test was performed to evaluate the reviewer scores. The t test was used to evaluate the SNR. The Fleiss κ coefficient was calculated to examine interreader agreement. RESULTS In 23 cases, spiral spin-echo was scored over Cartesian TSE in flow artifact reduction (P < .001). In 21 cases, spiral spin-echo was rated superior in subjective preference (P < .001). Ten patients were identified with lesions, and no statistically significant difference in lesion conspicuity was observed between the 2 sequences. There was no statistically significant difference in SNR between the 2 techniques. The Fleiss κ coefficient was 0.79 (95% confidence interval, 0.65-0.93). CONCLUSIONS The proposed spiral spin-echo pulse sequence provides postcontrast images with minimal flow artifacts at a faster scanning time than its Cartesian TSE counterpart.
منابع مشابه
Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملInversion-recovery echo-planar MR in adult brain neoplasia.
PURPOSE A T1-weighted multishot inversion-recovery (IR) echo-planar MR imaging (EPI) sequence was developed to improve intracranial tissue differentiation; its diagnostic utility was compared with that of conventional axial T1-weighted spin-echo and axial T2-weighted turbo spin-echo sequences. METHODS Eighteen patients with known or suspected primary or metastatic brain neoplasia were imaged ...
متن کاملMR imaging of Sturge-Weber syndrome: role of gadopentetate dimeglumine and gradient-echo techniques.
Five patients with Sturge-Weber syndrome were evaluated by conventional noncontrast spin-echo MR imaging, a gradient-recalled echo (GRE) technique, and T1-weighted spin-echo imaging after administration of gadopentetate dimeglumine. In four of five cases the full extent of intracranial disease was appreciated only on the postcontrast images. In one patient precontrast and GRE images were entire...
متن کاملPreliminary evaluation of fluid-attenuated inversion-recovery MR in the diagnosis of intracranial tumors.
PURPOSE To report our preliminary results in the application of a turbo fluid-attenuated inversion-recovery (FLAIR) MR technique to the diagnosis of intracranial tumors and to assess the clinical usefulness of this technique. METHODS Thirty-four patients with various intracranial tumors were studies with MR imaging, including a turbo FLAIR sequence. FLAIR images were compared with images obta...
متن کاملGRASE (gradient- and spin-echo) MR of the brain.
PURPOSE To assess the clinical utility of GRASE (gradient- and spin-echo) MR imaging of the brain by comparing it with the T2-weighted turbo spin-echo technique. METHODS Fifty-three consecutive patients referred for MR imaging of the brain were studied with T2-weighted turbo spin-echo and GRASE techniques, matched for effective echo time (110 milliseconds), echo train length (eight), and spat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 37 4 شماره
صفحات -