The histological and elemental characterisation of corrosion particles from taper junctions

نویسندگان

  • S. Munir
  • R. A. Oliver
  • B. Zicat
  • W. L. Walter
  • W. K. Walter
  • W. R. Walsh
چکیده

OBJECTIVES This study aimed to characterise and qualitatively grade the severity of the corrosion particles released into the hip joint following taper corrosion. METHODS The 26 cases examined were CoC/ABG Modular (n = 13) and ASR/SROM (n = 13). Blood serum metal ion levels were collected before and after revision surgery. The haematoxylin and eosin tissue sections were graded on the presence of fibrin exudates, necrosis, inflammatory cells and corrosion products. The corrosion products were identified based on visible observation and graded on abundance. Two independent observers blinded to the clinical patient findings scored all cases. Elemental analysis was performed on corrosion products within tissue sections. X-Ray diffraction was used to identify crystalline structures present in taper debris. RESULTS The CoC/ABG Modular patients had a mean age of 64.6 years (49.4 to 76.5) and ASR/SROM patients had a mean age of 58.2 years (33.3 to 85.6). The mean time in situ for CoC/ABG was 4.9 years (2 to 6.4) and ASR/SROM was 6.1 years (2.5 to 8.1). The blood serum metal ion concentrations reduced following revision surgery with the exception of Cr levels within CoC/ABG. The grading of tissue sections showed that the macrophage response and metal debris were significantly higher for the ASR/SROM patients (p < 0.001). The brown/red particles were significantly higher for ASR/SROM (p < 0.001). The taper debris contained traces of titanium oxide, chromium oxide and aluminium nitride. CONCLUSION This study characterised and qualitatively graded the severity of the corrosion particles released into the hip joint from tapers that had corrosion damage.Cite this article: S. Munir, R. A. Oliver, B. Zicat, W. L. Walter, W. K. Walter, W. R. Walsh. The histological and elemental characterisation of corrosion particles from taper junctions. Bone Joint Res 2016;5:370-378. DOI: 10.1302/2046-3758.59.2000507.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Particle formation, deposition, and particle induced corrosion in large-scale medium-speed diesel engines

The objective of this work was to study the formation of particles and their morphology and chemical composition in large-scale diesel engines operating with low-grade residual fuel oils. The effect of a Mg-based fuel oil additive on exhaust gas particles was also investigated. Particle characteristics were determined by means of the methods of aerosol technology, chemical analyses, and electro...

متن کامل

Fretting and Corrosion in Modular Shoulder Arthroplasty: A Retrieval Analysis

Tribocorrosion in taper junctions of retrieved anatomic shoulder arthroplasty implants was evaluated. A comparison of the tribocorrosion between cobalt-chromium and titanium alloy stems was conducted and the observations were correlated with the individual's clinical data. Adverse effects caused by metal debris and subsequent elevated serum metal ion levels are frequently reported in total hip ...

متن کامل

STUDY ON CORROSION BEHAVIOR OF COBALT NANO COMPOSITE COATINGS

Metal matrix nano composite coatings possess enhanced properties such as corrosion and wear resistance. This paper aims to study the corrosion behavior of pure Co and Co-BN nano composite coatings deposited with different particles concentration (5-20 g L-1) on copper substrates using electroplating technique. Morphology and elemental compositions of the coatings were investigated by means of s...

متن کامل

Characterisation and Corrosion Performance of MultilayerNano Nickel Coatings on AZ31 Magnesium Alloy

Ni-P and Ni layers multilayer coatings were applied to AZ31 magnesium alloy utilizing electroless and electrodeposition procedures. The aim of the project was to decrease cracks and increase corrosion resistance of the coatings. In order to compare the coatings, the effect of single layer electroless Ni-P coatings with different thicknesses was also investigated. The microstructure and phase co...

متن کامل

Surface microsurgery: taper section preparation

Surface microsurgery is the science of preparing surface layers, such as oxide scales and coatings, for characterisation of their microstructure and composition, by conventional surface analytical techniques, such as SEM, EPMA, SIMS etc. A surface microsurgery procedure often employed involves the preparation of a taper section. Using relatively simple equipment, significant improvements have b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016