Radiation exposure during fixation of femoral trochanteric fractures.

نویسندگان

  • J S Sidhu
  • T Kadni
چکیده

Radiation exposure to the surgeon and patient was measured in 14 patients during internal fixation of trochanteric fractures of the femur. Dosimetry studies were also done to determine the directions of maximum scatter production. The results indicated that the standard lead apron suffices for adequate gonadal and bone marrow shielding but the surgeon is still exposed to significant radiation levels to the extremities and neck. Based on these findings some recommendations for reduction of radiation exposure to the surgeon are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proximal Femoral Nail versus Dynamic Hip Screw Fixation for Trochanteric Fractures: A Meta-Analysis of Randomized Controlled Trials

BACKGROUND The purpose of this meta-analysis was to find out whether the proximal femoral nail was better than the dynamic hip screw in the treatment of trochanteric fractures with respect to operation time, blood transfusion, hospital stay, wound complications, number of reoperation, and mortality rate. METHODS All randomized controlled trials comparing proximal femoral nail and dynamic hip ...

متن کامل

Trochanteric Fracture of a Congenital/Developmental Dislocation of the Hip in an Elderly Woman: A Case Report

An 87-year-old woman with a residual dislocated hip suffered a trochanteric fracture on the ipsilateral side. The fracture was treated by open reduction and internal fixation surgery with good results. To treat a proximal femoral fracture of the residual dislocated hip in an elderly patient, the patient’s overall status, pre-fracture ability, hip joint configuration, and fracture pattern should...

متن کامل

Total Hip Replacement after Failed Internal Fixation of Trochanteric Femoral Fractures

Background: Failure of fixation of trochanteric fractures of the femur results in great disability and pain. Hip arthroplasty is a helpful reconstructive procedure in patients with poor bone stock, avascular necrosis of the femoral head, associated with damaged acetabular articular cartilage. Objective: This prospective study is to evaluate clinically and radiologically, the early results of to...

متن کامل

Wiring Techniques for the Fixation of Trochanteric Fragments during Bipolar Hemiarthroplasty for Femoral Intertrochanteric Fracture: Clinical Study and Technical Note

PURPOSE Femoral intertrochanteric fractures are common in the elderly. Appropriate surgical fixation of trochanteric fracture fragments can restore normal anatomical structure and ambulation, and can aid in the recovery of biomechanical function of the hip. We evaluated clinical outcomes of bipolar hemiarthroplasty using a wiring technique for trochanteric fracture fragment fixation. MATERIAL...

متن کامل

Treatment of Unstable Trochanteric Femur Fractures: Proximal Femur Nail Versus Proximal Femur Locking Compression Plate.

Unstable trochanteric femur fractures are common fractures that are difficult to manage. We conducted a prospective study to compare functional outcomes and complications of 2 different implant designs, proximal femur nail (PFN) and proximal femur locking compression plate (PFLCP), used in internal fixation of unstable trochanteric femur fractures. On hospital admission, 48 patients with unstab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Medical journal of Malaysia

دوره 43 2  شماره 

صفحات  -

تاریخ انتشار 1988