PURPOSE To characterize the effect of fat on modified Look-Locker inversion recovery (MOLLI) T1 maps of the liver. The balanced steady-state free precession (bSSFP) sequence causes water and fat signals to have opposite phase when repetition time (TR) = 2.3 msec at 3T. In voxels that contain both fat and water, the MOLLI T1 measurement is influenced by the choice of TR. MATERIALS AND METHODS MOLLI T1 measurements of the liver were simulated using the Bloch equations while varying the hepatic lipid content (HLC). Phantom scans were performed on margarine phantoms, using both MOLLI and spin echo inversion recovery sequences. MOLLI T1 at 3T and HLC were determined in patients (n = 8) before and after bariatric surgery. RESULTS At 3T, with HLC in the 0-35% range, higher fat fraction values lead to longer MOLLI T1 values when TR = 2.3 msec. Patients were found to have higher MOLLI T1 at elevated HLC (T1 = 929 ± 97 msec) than at low HLC (T1 = 870 ± 44 msec). CONCLUSION At 3T, MOLLI T1 values are affected by HLC, substantially changing MOLLI T1 in a clinically relevant range of fat content. J. Magn. Reson. Imaging 2016;44:105-111.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution modified look-locker inversion recovery (HR-MOLLI) for RV extracellular volume fraction at 3T and 1.5T: A feasibility study

Background Cardiac MR (CMR) is the reference standard for assessing macroscopic myocardial scar. Determination of the extracellular volume fraction (ECV) by T1 estimation using the modified Look-Locker inversion recovery (MOLLI) correction enables quantitation of diffuse fibrosis. The purpose of this study is to evaluate the feasibility and reproducibility of an optimized high-resolution MOLLI ...

متن کامل

Phantom validation of 17 and 11 heartbeat MOLLI T1 mapping sequence at 3T

Background and objective The Modified Look-Locker Inversion-Recovery (MOLLI) sequence (Messroghli, et al, JMRI, 2007) was optimized for myocardial T1 mapping on 1.5T. However, little data exists on T1 mapping at 3T. The standard MOLLI sequence uses three inversion-recovery blocks to acquire 11 images over 17 heartbeats (HB). The long breath hold could limit its clinical application in patients ...

متن کامل

Shortened modified look-locker inversion recovery for myocardial T1 mapping in healthy volunteers: determination of reference T1 relaxation times at 3 Tesla MR according to different contrast injection methods

Background Reference preand post-contrast T1 values of myocardium have been reported at 1.5T but those values at 3T have not been fully established. Additionally, the physical properties of gadolinium contrast agents significantly affect the myocardial voxel T1 value. There have been two different contrast injection methods in the literatures. The aim of our study was to establish preand post-c...

متن کامل

Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: a T1 mapping primer.

BACKGROUND The purpose of this work was to evaluate different magnetization preparation and readout sequences for modified Look-Locker inversion recovery (MOLLI) toward improved T1 mapping in the heart. Elements investigated include: catalyzation sequences to prepare the magnetization before readout, alternate k-space trajectories, a spoiled gradient recalled echo readout, and a 5b(3b)3b MOLLI ...

متن کامل

Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold

BACKGROUND T1 mapping allows direct in-vivo quantitation of microscopic changes in the myocardium, providing new diagnostic insights into cardiac disease. Existing methods require long breath holds that are demanding for many cardiac patients. In this work we propose and validate a novel, clinically applicable, pulse sequence for myocardial T1-mapping that is compatible with typical limits for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 44  شماره 

صفحات  -

تاریخ انتشار 2016