The unstable total hip replacement.
نویسندگان
چکیده
Instability after total hip arthroplasty (THA) is not a rare occurrence. Numerous factors have been associated with dislocation including surgical approach, implant design, failure to restore proper hip mechanics and soft tissue restraints, and patient variables such as early postoperative compliance, soft tissue integrity, and neurologic conditions such as poor proprioception. A thorough understanding of the mechanism of dislocation, timing, and direction of dislocation is mandatory in formulating an approach toward treatment. The radiographic evaluation should evaluate hip mechanics including component orientation, adequacy of leg lengths, and restoration of offset in the frontal and sagittal planes. The treatment of the unstable total hip replacement is based on numerous variables including the timing of instability, direction, and mechanism. Instability in the early postoperative period in the hip with proper orientation and restored mechanics often is treated successfully with patient reeducation and use of adjunctive bracing. The treatment of the recurrent dislocator can be more difficult. Although reestablishing proper mechanics and orientation can be successful in many instances, some patients continue to have dislocation. Constrained acetabular liners have significantly improved the success rate of reducing the incidence of dislocation, but problems related to premature wear and dislodgement are a major concern. The use of larger articulating bearing surfaces used with the newer cross-linked polyethylene may provide the solution to instability minimizing the concerns related to constrained components.
منابع مشابه
Revision of an unstable HELICA endoprosthesis with a Zurich cementless total hip replacement.
A six-year-old, female, spayed Labrador Retriever was evaluated for progressive lameness of one year duration, ending in non-weight-bearing of the right hindlimb. The dog had a history of severe coxarthrosis of both hip joints, and had a HELICA hip prosthesis implanted in the right hip 18 months before. On survey radiographs, the acetabular and femoral components appeared unstable, with a large...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملBilateral Staged Total Hip Replacement and the Natural Progress of an Untreated Case of Developmental Dysplasia (Dislocation) of the Hip: A Clinical Case Report by the Surgeon and the Patient
The natural history of an untreated case of a Developmental Dysplasia (Dislocation) of the Hip (DDH) associated with multiple congenital abnormalities is reported in a 55-years-old man. The patient’s complaints and the varieties of the typical manifestations emerged in other parts of the body throughout the life are reviewed and discussed as comorbidities of a dysplastic condition. Two-stage bi...
متن کاملThe cementless anatomic medullary locking femoral component: an independent clinical and radiographic assessment.
OBJECTIVE To review the clinical performance of the anatomic medullary locking (AML) femoral stem in total hip arthroplasty. DESIGN A clinical and radiographic review. SETTING A tertiary lower limb joint replacement centre. PATIENTS Two hundred and twenty-one patients with noninflammatory gonarthrosis. INTERVENTIONS Two hundred and twenty-seven primary total hip arthroplasties with the ...
متن کاملThoracic vertebral body fracture after total hip replacement in diffuse idiopathic skeletal hyperostosis.
This article describes the critical clinical sequelae of a patient with diffuse idiopathic skeletal hyperostosis who sustained an acute iatrogenic thoracic vertebral body fracture with subsequent spinal cord injury after a total hip replacement, with a final lethal course.A 57-year-old woman was referred to the authors' institution after undergoing a total hip replacement in the supine position...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 420 شماره
صفحات -
تاریخ انتشار 2004