A New Glaucoma Severity Score Combining Structural and Functional Defects.
نویسندگان
چکیده
Background In order to assess glaucoma severity and to compare the success of surgical and medical therapy and study outcomes, an objective and independent staging tool is necessary. A combination of information from both structural and functional testing is probably the best approach to stage glaucomatous damage. There has been no universally accepted standard for glaucoma staging. The aim of this study was to develop a Glaucoma Severity Score (GSS) for objective assessment of a patient's glaucoma severity, combining both functional and structural information. Materials and methods The Glaucoma Severity Score includes the following 3 criteria: superior and inferior Retinal Nerve Fibre Layer (RNFL) thickness, perimetric mean defect (MD), and agreement of anatomical and perimetric defects, as assessed by two glaucoma specialists. The specialists defined a staging tool for each of the 3 criteria in a consensus process, assigning specific characteristics to a scale value between 0 and 2 or 0 and 3, respectively. The GSS ranges between 0 and 10 points. In a prospective observational study, the data of 112 glaucoma patients were assessed independently by the two specialists according to this staging tool. Results The GSS was applied to 112 eyes and patients (59.8 % female) with a mean age of 66.3 ± 13.1 years. Mean GSS was 4.73 points. Cohen's kappa coefficient was determined to measure inter-rater agreement between glaucoma specialists for the third criterion. With κ = 0.83, the agreement was very good. Thus, all 3 criteria of the GSS may be regarded as objective. Conclusions The Glaucoma Severity Score is an objective tool, combining both structural and functional characteristics, and permitting comparison of different patients, populations and studies. The Glaucoma Severity Score has proven effective in the objective assessment of 112 glaucoma patients and is relatively user-friendly in clinical practice. A comparative study of the GSS with the results of the FORUM® Glaucoma Workplace (Carl Zeiss Meditec AG, Jena, Germany) will be the next step. If outcomes match, the Glaucoma Severity Score can be accepted as a promising tool to stage glaucoma and monitor changes objectively in patients when comparing glaucoma progression in study analyses.
منابع مشابه
Depression and Quality of Life in Patients with Glaucoma
Purpose: To investigate the frequency of depression and quality of life in patients with glaucoma. Methods: This cross-sectional study included 204 patients (102 males and 102 females) with a mean age of 58.9±11.96 and a range of 40 to 85 years old. Achromatic perimetry was performed, using the HFA SITA-standard 24-2. Severity was stratified according to the Nelson Glaucoma Severity Scale (base...
متن کاملEvaluation of a New Scoring System for Retinal Nerve Fiber Layer Photography Using HRA1 in 964 Eyes
PURPOSE To evaluate retinal nerve fiber layer (RNFL) defect by a new scoring system for RNFL photography using the Heidelberg Retina Angiograph 1 (HRA1). METHODS This retrospective study included 128 healthy eyes and 836 primary open-angle glaucoma eyes. The RNFL photography using HRA1 was interpreted using a new scoring system, and correlated with visual field indices of standard automated p...
متن کاملAsymmetric Macular Structural Damage Is Associated With Relative Afferent Pupillary Defects in Patients With Glaucoma
PURPOSE We examined the relationship between relative afferent pupillary defects (RAPDs) and macular structural damage measured by macular thickness and macular ganglion cell-inner plexiform layer (mGCIPL) thickness in patients with glaucoma. METHODS A cross-sectional study was done of 106 glaucoma patients and 85 healthy individuals from the Diagnostic Innovations in Glaucoma Study. All subj...
متن کاملAssessment of Structural Glaucoma Progression
PURPOSE To provide an update on the role of optic nerve head and peripapillary retinal nerve fiber layer imaging in monitoring glaucoma progression. METHODS Review of literature. RESULTS Imaging technologies, such as optical coherence tomography, scanning laser polarimetry, and confocal scanning laser ophthalmoscopy, objectively and quantitatively measure the structural change associated wi...
متن کاملStructural and functional assessment of the macular region in patients with glaucoma.
PURPOSE To investigate the correlation of a structural measure of the macular area (optical coherence tomography (OCT)) with two functional measures (10-2 Humphrey visual field (HVF) and multifocal visual evoked potential (mfVEP)) of macular function. METHODS 55 eyes with open-angle glaucoma were enrolled. The 10-2 HVF was defined as abnormal if clusters of > or =3 points with p<5%, one of wh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Klinische Monatsblatter fur Augenheilkunde
دوره 234 4 شماره
صفحات -
تاریخ انتشار 2017