Elemental thin film depth profiles by ion beam analysis using simulated annealing—a new tool
نویسنده
چکیده
Rutherford backscattering spectrometry (RBS) and related techniques have long been used to determine the elemental depth profiles in films a few nanometres to a few microns thick. However, although obtaining spectra is very easy, solving the inverse problem of extracting the depth profiles from the spectra is not possible analytically except for special cases. It is because these special cases include important classes of samples, and because skilled analysts are adept at extracting useful qualitative information from the data, that ion beam analysis is still an important technique. We have recently solved this inverse problem using the simulated annealing algorithm. We have implemented the solution in the ‘IBA DataFurnace’ code, which has been developed into a very versatile and general new software tool that analysts can now use to rapidly extract quantitative accurate depth profiles from real samples on an industrial scale. We review the features, applicability and validation of this new code together with other approaches to handling IBA (ion beam analysis) data, with particular attention being given to determining both the absolute accuracy of the depth profiles and statistically accurate error estimates. We include examples of analyses using RBS, non-Rutherford elastic scattering, elastic recoil detection and non-resonant nuclear reactions. High depth resolution and the use of multiple techniques simultaneously are both discussed. There is usually systematic ambiguity in IBA data and Butler’s example of ambiguity (1990 Nucl. Instrum. Methods B 45 160–5) is reanalysed. Analyses are shown: of evaporated, sputtered, oxidized, ion implanted, ion beam mixed and annealed materials; of semiconductors, optical and magnetic multilayers, superconductors, tribological films and metals; and of oxides on Si, mixed metal silicides, boron nitride, GaN, SiC, mixed metal oxides, YBCO and polymers.
منابع مشابه
Processing for optically active erbium in silicon by film co-deposition and ion-beam mixing
Techniques of film deposition by co-evaporation, ion-beam assisted mixing, oxygen ion implantation, and thermal annealingwere been combined in a novel way to study processing of erbium-in-silicon thinfilm materials for optoelectronics applications. Structures with erbium concentrations above atomic solubility in silicon and below that of silicide compoundswere prepared by vacuum co-evaporation ...
متن کاملIn situ analysis of elemental depth distributions in thin films by combined evaluation of synchrotron x-ray fluorescence and diffraction
In this work we present a method for the in situ analysis of elemental depth distributions in thin films using a combined evaluation of synchrotron x-ray fluorescence and energy-dispersive x-ray diffraction signals. We recorded diffraction and fluorescence signals simultaneously during the reactive annealing of thin films. By means of the observed diffraction signals, the time evolution of phas...
متن کاملEffect of bias voltage on structural and mechanical characteristics of diamond-like carbon thin film applied by ion beam deposition
This study, investigates the effect of bias voltage on structural changes of diamond-like carbon thin film created by ion beam deposition is investigated. For this purpose, the bias voltage in the values of 0 V, -50 V, -100 V and -150 V on the AA5083 aluminum alloy was considered. Raman spectroscopy was used to evaluate structural. Influence of the bias voltage on the thickness and roughness of...
متن کاملAtmospheric oxygen in Mn doped GaAs/GaAs(0 0 1) thin films grown by molecular beam epitaxy
Mn doped GaAs thin films were grown using molecular beam epitaxy at high and low substrate temperatures. The elemental concentration depth profiles in the thin films were determined by using Auger electron spectroscopy combined with ion etching. The Mn concentration is higher near the surface and then decreases with depth for films grown at high substrate temperatures. The Mn concentration prof...
متن کاملThe nuclear microprobe: a unique instrument
There are several features characterising high-energy ion interactions with matter which enables techniques which utilise the high-energy ion beam to have unique or advantageous characteristics. (i) The lack of primary particle bremsstrahlung enables Particle Induced X-ray Emission (PIXE) to be carried out with very little X-ray background, and therefore correspondingly high analytical sensitiv...
متن کامل