Determination of ethanol in beverages by flow injection, pervaporation and density measurements.

نویسندگان

  • J González-Rodríguez
  • P Pérez-Juan
  • M D Luque de Castro
چکیده

A fast, clean and easy to automate flow injection-pervaporation method for the determination of ethanol in different beverages using density measurements is proposed. The method is based on separation of the ethanol from the sample using a pervaporation module; the analyte being collected in water as acceptor liquid. The density of this water-alcohol mixture is measured at the detector. After optimisation by either a univariate or multivariate approach as required, a linear range between 0 and 40% was established. Then, the assessment of the method versus a reference one was studied in terms of repeatability (0.12% v/v), reproducibility (0.32% v/v), detection limit (0.11% v/v) and traceability. The sample throughput was 15 samples h(-1). The method was in agreement with the reference methods used in the European Union.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhanced Bioethanol Production in Batch Fermentation by Pervaporation Using a PDMS Membrane Bioreactor

The integration of batch fermentation and membrane-based pervaporation process in a membrane bioreactor (MBR) was studied to enhance bioethanol production compared to conventional batch fermentation operated at optimum condition. For this purpose, a laboratory-scale MBR system was designed and fabricated. Dense hydrophobic Polydimethylsiloxane (PDMS) membrane was used for pervaporation. For fer...

متن کامل

FLOW INJECTIOW DETERMINATION OF FLUORIDE BY MURTN-ALUMINUM REAGEM WITH SPECTROEUORIMIETRIC DETECTION

A flow injection system is reported for the determination of fluoride based on its effects on the fluorescence intensity of Al-morin complex at pH 3.0 in ethanol-warn mixture. The effect of important parameters such as excitation and emission wavelengths, pH, reagents concenkations, flow rate of the carrier stream, sample injection volume, time of measurepent and interferences are reported. ...

متن کامل

Two-parameter determination in vinegar by a flow injection-pervaporation system.

A flow injection method (FI) for the sequential determination of ethanol and acetic acid in vinegar is reported. The determination of ethanol is based on the oxidation of the pervaporated ethanol by K2Cr2O7. The acetic acid is determined by an acid-base reaction with Thymol Blue as the indicator. Both reactions are monitored photometrically at 600 nm using a single detector. Optimisation studie...

متن کامل

A flow injection biamperometric method for determination of total antioxidant capacity of alcoholic beverages using bienzymatically produced ABTS

Development of flow injection analysis (FIA) is reported for determination of total antioxidant capacity of alcoholic beverages (wines and spirits) by bienzymatically produced ABTS + and electrochemical detector using interdigitated gold electrode (IDE). The method is based on biamperometric measurements using ABTS jABTS redox couple. During the analysis, ABTS radical cation was bienzymatically...

متن کامل

Sequential spectrophotometric determination of methanol and iron in vinegar by a flow injection-pervaporation method.

An easily automatable sequential flow-injection-pervaporation method is proposed for the photometric determination of methanol and iron in vinegar. The method is based on separation of the methanol from the sample matrix by pervaporation followed by its oxidation to formaldehyde with permanganate, decolouration of the latter with S(2)O(5)(2-), and subsequent reaction of formaldehyde with p-rosa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 59 4  شماره 

صفحات  -

تاریخ انتشار 2003