Assessment of Ge-doped optical fibres subjected to x-ray irradiation

نویسندگان

  • S A Ibrahim
  • S S Che Omar
  • S Hashim
  • G A Mahdiraji
  • N M Isa
چکیده

We have reported the thermoluminescence (TL) response of five different diameters ~120, 241, 362, 483, and 604 μm of 6 mol percent Ge-doped optical fibres. The perfomance of the Ge-doped optical fibre are compared with commercially available TLD-100 chips (LiF:Mg,Ti) in terms of their sensitivity and minimum detectable dose (MDD). The irradiation was performed using X-ray machine (Model ISO ‘Narrow Spectrum Series’) provided by the Malaysian Nuclear Agency (MNA) at 60 kV X-ray irradiation in low doses ranging from 1-10 mGy. The results show the linear TL dose response from the fibres up to 10 mGy. The smallest diameter of 120 μm optical fibre shows the highest TL dose response compared to above mentioned fibres. The minimum detectable dose (MDD) is 0.82, 0.20, 0.14, 0.08, and 0.13 mGy for Ge-doped with diameters of 120, 241, 362, 483 and 604 μm. All TL materials show the MDD value within the delivered dose 0.01-1.00 mGy subjected to x-ray irradiation. The Ge-doped fibre with diameter of 483 μm was matched the MDD value of TLD-100 chips that equivalent to 0.08 mGy at the same irradiation. We have observed that among the five different diameters of optical fibre, 120 μm shows the best results and its better response than TLD-100 chips (by a factor of 5). The linear response at low dose levels makes this optical fibre most suitable for medical application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The thermoluminescence response of doped SiO2 optical fibres subjected to fast neutrons.

This paper describes a preliminary study of the thermoluminescence (TL) response of doped SiO(2) optical fibres subjected to (241)AmBe neutron irradiation. The TL materials, which comprise Al- and Ge-doped silica fibres, were exposed in close contact with the (241)AmBe source to obtain fast neutron interactions through use of measurements obtained with and without a Cd filter (the filter being ...

متن کامل

Sonochemical synthesis of undoped and Co-doped ZnO nanostructures and investigation of optical and photocatalytic properties

In this paper, undopedZnO and Co-ZnOnano structureswith different molar ratio of Cobalt have been synthesized by the sonochemical method. Structure have been characterized by Fourier Transform (FTIR) and UV–Vis spectroscopy,Scanning Electron Microscopy (SEM), Energy Dispersive Analytical X-Ray (EDAX), and X-Ray Diffraction (XRD) methods. Moreover, the direct band gap has been calculated by Tauc...

متن کامل

Sonochemical synthesis of undoped and Co-doped ZnO nanostructures and investigation of optical and photocatalytic properties

In this paper, undopedZnO and Co-ZnOnano structureswith different molar ratio of Cobalt have been synthesized by the sonochemical method. Structure have been characterized by Fourier Transform (FTIR) and UV–Vis spectroscopy,Scanning Electron Microscopy (SEM), Energy Dispersive Analytical X-Ray (EDAX), and X-Ray Diffraction (XRD) methods. Moreover, the direct band gap has been calculated by Tauc...

متن کامل

Preparation of nanocomposite scintillator of ZnS doped with Ag, Cu and AgCu for alpha particle detection

ZnS nanoparticles (NPs) doped with ‎Ag‎, ‎Cu‎, ‎and AgCu were synthesized using hydrothermal‎ ‎method in water solution‎. ‎The NPS are characterized by X-ray diffraction (XRD)‎, ‎energy-dispersive‎ ‎X-ray spectroscopy scanning (EDX)‎, ‎scanning electron‎ ‎microscopy (SEM) and dynamic light scattering (DLS)‎. ‎The produced NPs have approximately hexagonal structure and a cubic zinc blended struc...

متن کامل

Low-dose photon irradiation response of Ge and Al-doped SiO2 optical fibres.

We have investigated the thermoluminescent response and fading characteristics of germanium- and aluminium-doped SiO(2) optical fibres. These optical fibres were placed in a solid phantom and irradiated using 6 and 10 MV photon beams at doses ranging from 0.02 to 0.24 Gy delivered using a linear accelerator. In fading studies, the TL measurements were continued up to 14 days post-irradation. We...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014