Comparative evaluation of the microplate nitrate reductase assay and the rezasurin microtitre assay for the rapid detection of multidrug resistant Mycobacterium tuberculosis clinical isolates.

نویسندگان

  • Ahmet Yilmaz Coban
  • Meltem Uzun
  • Alper Akgunes
  • Belma Durupinar
چکیده

The microplate nitrate reductase assay (MNRA) and the rezasurin microtitre assay (REMA) were used for the susceptibility testing of 73 clinical isolates and the results were compared with those that were obtained using the Bactec 460 TB and Bactec MGIT 960 systems. The REMA and the MNRA were performed in 96-well plates. For the REMA, the concentrations of isoniazid (INH) and rifampicin (RIF) ranged from 1.0-0.01 µg/mL and 2.0-0.03 µg/mL, respectively. For the MNRA, the INH concentration was between 1.0-0.03 µg/mL and the RIF concentration was between 2.0-0.06 µg/mL. For the MNRA, the sensitivity, specificity, positive predictive value, negative predictive value and INH/RIF agreement were 100/95.6, 97.6/100, 96.8/100, 100/98 and 98.6/98.6, respectively, and for the REMA, they were 100/91.3, 90.4/100, 88.5/100, 100/96.1 and 94.5/97.2, respectively. Our data suggest that these two rapid, low-cost methods may be inexpensive, alternative assays for the rapid detection of multidrug resistant tuberculosis in low-income countries.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of four colourimetric susceptibility tests for the rapid detection of multidrug-resistant Mycobacterium tuberculosis isolates

The purpose of this study is to evaluate four rapid colourimetric methods, including the resazurin microtitre assay (REMA), malachite green decolourisation assay (MGDA), microplate nitrate reductase assay (MNRA) and crystal violet decolourisation assay (CVDA), for the rapid detection of multidrug-resistant (MDR) tuberculosis. Fifty Mycobacterium tuberculosis isolates were used in this study. Ei...

متن کامل

Comparative evaluation of the nitrate reduction assay, the MTT test, and the resazurin microtitre assay for drug susceptibility testing of clinical isolates of Mycobacterium tuberculosis.

OBJECTIVES To evaluate the performance of three rapid low-cost methods for the detection of resistance to first-line drugs in Mycobacterium tuberculosis. METHODS One hundred M. tuberculosis clinical isolates were tested by the nitrate reductase assay (NRA), the MTT test and the resazurin microtitre assay (REMA), and the results compared with those obtained with the gold standard proportion me...

متن کامل

Utility of nitrate reductase assay for detection of multidrug-resistant Mycobacterium tuberculosis in a low resource setting.

Introduction. The performance of a drug susceptibility test may change when moving from the research stage to implementation on a population level in actual public health practice. Objective. The performance of a rapid drug susceptibility test was described for detecting multidrug-resistant Mycobacterium tuberculosis when implemented in the routine workflow of a low-resource reference laborator...

متن کامل

Investigation of the rpoB Mutations Causing Rifampin Resistance by Rapid Screening in Mycobacterium Tuberculosis in North-East of Iran

Background and Objectives: The incidence of rifampin-resistant strains of Mycobacterium tuberculosis has attracted more attention than the tuberculosis infection due to laborious treatment and control. Recognizing the Mycobacterium tuberculosis genotypes involving in drug resistance via multiplex PCR, a simple and rapid genotyping method, is an emergency for better tre...

متن کامل

Rapid detection of multidrug-resistant Mycobacterium tuberculosis in Cotonou (Benin) using two low-cost colorimetric methods: resazurin and nitrate reductase assays.

We have evaluated two simple, rapid and low-cost colorimetric methods for the detection of multidrug-resistant Mycobacterium tuberculosis. A total of 151 M. tuberculosis strains were tested for resistance to rifampicin (RMP) and isoniazid by resazurin microplate assay (REMA) and nitrate reductase assay (NRA) in comparison with the conventional proportion method (PM) on Löwenstein-Jensen medium....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Memorias do Instituto Oswaldo Cruz

دوره 107 5  شماره 

صفحات  -

تاریخ انتشار 2012