Quantitative analysis of autoinducing peptide I (AIP-I) from Staphylococcus aureus cultures using ultrahigh performance liquid chromatography–high resolving power mass spectrometry By: Hiyas

نویسندگان

  • A. Junio
  • Daniel A. Todd
  • Keivan A. Ettefagh
  • Brandie M. Ehrmann
  • Jeffrey S. Kavanaugh
  • Alexander R. Horswill
  • Nadja B. Cech
چکیده

Staphylococcus aureus infections acquired in hospitals now cause more deaths per annum in the US than does HIV/AIDS. Perhaps even more alarming is the rise in community associated methicillin-resistant S. aureus (CA-MRSA) infections, which have spread out of hospital settings and are infecting otherwise healthy individuals. The mechanism of enhanced pathogenesis in CA-MRSA remains unclear, but it has been postulated that high activity in the agr quorumsensing system could be a contributing factor. The purpose of this study was to develop a quantitative method for analysis of autoinducing peptide I (AIP-I), the activating signal for the agr system in S. aureus. An effective method was developed using ultrahigh performance liquid chromatography (UHPLC) coupled to electrospray ionization mass spectrometry with an LTQ Orbitrap mass spectrometer. Relying on the exceptional resolving power and mass accuracy of this instrument configuration, it was possible to quantify AIP-I directly from the complex growth media of S. aureus cultures with a limit of detection (LOD) of 0.25 μM and a linear dynamic range of 2.6 to 63 μM. The method was then employed to monitor time-dependent production of AIP-I by S. aureus cultures, and it was observed that AIP-I production reached a maximum and leveled off after approximately 16 h. Finally, it was determined that virulence of S. aureus was correlated with AIP-I production in some (but not all) strains analyzed. UHPLC | Staphylococcus aureus | Virulence | AIP-I | Mass spectrometry

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biosynthesis of Staphylococcus aureus autoinducing peptides by using the synechocystis DnaB mini-intein.

The Agr quorum-sensing system of Staphylococcus aureus modulates the expression of virulence factors in response to autoinducing peptides (AIPs). The peptides are seven to nine residues in length and have the C-terminal five residues constrained in a thiolactone ring. We have developed a new method to generate AIP structures using an engineered DnaB mini-intein from Synechocystis sp. strain PCC...

متن کامل

N-Methyl and peptoid scans of an autoinducing peptide reveal new structural features required for inhibition and activation of AgrC quorum sensing receptors in Staphylococcus aureus.

We report the first N-methyl and peptoid residue scans of a full-length autoinducing peptide (AIP), AIP-III, used by Staphylococcus aureus for quorum sensing (QS). Biological evaluation of these AIP-III analogues uncovered new features of the AIP-III scaffold that can be tuned to develop chemical probes of QS in all four groups of S. aureus (I-IV).

متن کامل

High-Throughput and Comprehensive Lipidomic Analysis Using Ultrahigh-Performance Supercritical Fluid Chromatography-Mass Spectrometry.

New analytical approach for high-throughput and comprehensive lipidomic analysis of biological samples using ultrahigh-performance supercritical fluid chromatography (UHPSFC) with electrospray ionization-mass spectrometry (ESI-MS) is presented in this work as an alternative approach to established shotgun MS or high-performance liquid chromatography-MS. The lipid class separation is performed b...

متن کامل

Key determinants of receptor activation in the agr autoinducing peptides of Staphylococcus aureus.

Staphylococcal pathogenesis is regulated by a two-component quorum-sensing system, agr, activated upon binding of a self-coded autoinducing peptide (AIP) to the receptor-histidine kinase, AgrC. The AIPs consist of a thiolactone macrocyle and an exocyclic "tail", both of which are important for function. In this report, characterization of the unique AIPs from the four known agr specificity grou...

متن کامل

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014