Validation of CBF measurement with non-invasive microsphere method (NIMS) compared with autoradiography method (ARG).
نویسندگان
چکیده
The purpose of this study is to examine the correlation of measured regional cerebral blood flow (rCBF) by means of a new microsphere method (non-invasive microsphere method), to the autoradiography (ARG) method, which is an established quantification method for 123I-IMP brain SPECT. The non-invasive microsphere (NIMS) method and ARG method were simultaneously applied to 30 patients, and quantified rCBF maps were calculated with each method. A significant correlation (r = 0.70: p < 0.001) was detected between mCBF values calculated with the NIMS and ARG methods. This new method seems to reliably quantify rCBF with brain SPECT.
منابع مشابه
A simple non-invasive I-123-IMP autoradiography method developed by modifying the simple non-invasive I-123-IMP microsphere method
Objective: We developed a simple non-invasive I-123-N-isopropyl-p-iodoamphetamine (123I-IMP) quantification method by analyzing chest RI-angiography and single photon emission computed tomography (SPECT) images based on the microsphere model (SIMS method). Theoretically, the SIMS method could be changed to the simple non-invasive ARG (SIARG) method by modifying the integrated washout ratio (WR)...
متن کاملA Simple Non-invasive I-123-IMP Autoradiography Method Developed by Modifying the Simple Non-invasive I-123-IMP Microsphere Method
Objectives We developed a simple non-invasive I-123-N-isopropyl-p-iodoamphetamine (123I-IMP) quantification method by analyzing chest RI-angiography and single photon emission computed tomography (SPECT) images based on the microsphere model (SIMS method). Theoretically, the SIMS method could be changed to the simple non-invasive ARG (SIARG) method by modifying the integrated washout ratio (WR)...
متن کامل[Measurements of cerebral blood flow by the noninvasive microsphere method with 123I-IMP and fan beam collimator: comparison with the continuous arterial blood sampling method].
PURPOSE AND METHODS The noninvasive microsphere (NIMS) method quantifies cerebral blood flow with N-isopropyl-p-[123I]-iodoamphetamine (123I-IMP) without blood sampling of a patient, but when a fan beam collimator is used for collecting raw data in single photon emission computed tomography (SPECT), the procedure is complicated because we have to change the collimator. In phantom and clinical s...
متن کاملDevelopment of an H(2)(15)O steady-state method combining a bolus and slow increasing injection with a multiprogramming syringe pump.
An (15)O-labeled water (H(2)(15)O) steady-state method for quantitative measurement of cerebral blood flow (CBF), which is less stressful to small animals with a few point blood sampling, was developed. After a simulation using a dose meter to achieve stable H(2)(15)O radioactivity in the blood with a multiprogramming syringe pump programmed for slowly increasing injection volume, 10 rats were ...
متن کامل[Application of collimator broad correction three dimensional ordered subsets expectation maximization for regional cerebral blood flow measurement].
Autoradiography (ARG) has been used for quantitative analysis of the cerebral blood flow using 123I-IMP, and the regional cerebral blood flow (rCBF) can be assessed more accurately with scatter and attenuation correction. Currently, the filtered back projection (FBP) method is generally used for image reconstruction. However, we anticipate obtaining more accurate rCBF by the ordered ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 15 1 شماره
صفحات -
تاریخ انتشار 2001