Evaluation of Structural Shielding Designs of X-Ray Linear Accelerator Scanner at the Port of Tema, Ghana
نویسنده
چکیده
This study was conducted to evaluate the shielding designs of a 6 MeV x-ray linear accelerator scanner used for cargo-container scanning at the port of Tema in Ghana. Workload of the facility had increased significantly over time necessitating review of the installed shielding. There had been introduction of x-ray unit with higher energy (from 5 MeV to 6 MeV) increasing absorbed dose per scan. The number of scans per day had increased from an average of 60 to 95 scans. New structures had been built around the facility without particular attention to their distances and orientations with respect to the radiation source. The principle that the product of the weekly time average dose rates (Rw) and the occupancy for a particular point of interest (location) should not exceed the design dose limit, P (i.e. P ≥ RwT) for that location was partly used to determine the adequacy of the shielding afforded by the barriers. In addition to P ≥ RwT, calculated and measured hourly time average dose rates (Rh) were used to establish the adequacy of the shieldings based on the dose limit of 0.5μSv/h for public and supervised areas (uncontrolled areas). The Rw, calculated Rh and measured Rh all fell below the dose limit showing that the primary and secondary barriers are adequate.
منابع مشابه
Shielding simulations for safe use of curtain electron accelerator by MCNP4C
In an electron curtain accelerator, when the electron beam passes through the titanium exit window of the accelerator chamber, X-ray photons are produced as a negative by-product of retarding accelerated electrons. Controlling the produced X-ray photons to avoid their detrimental effects or in fact, proper shielding of the accelerator is an important issue that has to be considered in the use o...
متن کاملProtective and dosimeter design of the stationary and mobile model truck inspection system with electron linear accelerator radiation source
In this work, calculations of leaked dose from vehicle inspection area, the absorbed dose by driver and operator, and the required concrete thickness for shielding the inspection area are presented using the Monte Carlo code MCNPX2.6. The X-ray source of the present vehicle inspection system is a LinatronMi6 accelerator, end of which has only been simulated in this study (the electron beam coll...
متن کاملIntroducing a novel Polyvinyl chloride/Tungsten composites for shielding against gamma and X-ray radiations
Introduction: This study introduces a novel polyvinyl chloride (PVC)/tungsten composites with characterization of their shielding properties by employing different techniques. Methods: The PVC/tungsten composites were produced by employing various weight fractions of tungsten micro-particles including 0, 20, and 40 % wt via melt blending method. In the next st...
متن کاملEvaluation of the Prevalence and Utility of Gonad Shielding in Pediatrics Undergoing Pelvic X-Ray
Background: Gonad shielding has been recommended during pelvic x-rays since the 1950s. The popular method of gonad shielding is placement a lead shield in the midline of the pelvis. The aim of this study was to evaluate the prevalence and utility of gonad shielding in pediatrics undergoing pelvic x-rays.Materials and MethodsFollowing study approval, we retrospectively retrieved data from the di...
متن کاملApplication of characteristic X-rays to measure linear attenuation coefficient of nano-composites used in shielding
Using of X-rays in different industries and especially in medical application is increasing. In this regard, designing of light and efficient protective material based on polymeric nanocomposites and precise study of the effect of adding nanoparticles with different sizes on the X-ray attenuation is necessary. In this study the epoxy nanocomposites with different percentages of copper oxide nan...