Optimized heart rate for 320-row cardiac CT can be feasibly predicted from prescan parameters

نویسندگان

  • Eriko Maeda
  • Nobuo Tomizawa
  • Kodai Yamamoto
  • Shigeaki Kanno
  • Masaaki Akahane
  • Kenji Ino
  • Masae Uehara
  • Aiko Sakamoto
  • Toshiaki Semboku
  • Rumiko Torigoe
  • Kuni Ohtomo
چکیده

To evaluate the degree of heart rate (HR) changes at rest (HRrest), during breath hold (HRtest), and during cardiac CT examinations (HRscan) in a large group of patients , and to derive and asses the feasibility of a predictive formula for HRscan. HRrest, HRtest, and HRscan were retrospectively compared in a total of 563 consecutive patients who underwent 320-row cardiac CT. Multiple regression analysis was performed to derive predictive formulae for HRscan in the entire study population and, in each group of patients with decreased (Dec) or increased (Inc) HR during breath hold. The predictive formula was evaluated as accurate when less than 5 % of the actual HRscan exceeded the predicted HRscan by ±5 beats per minute (bpm). The average values of the HRtest (65.3 ± 12.0 bpm) and HRscan (63.7 ± 11.9 bpm) significantly decreased from those of the HRrest (68.4 ± 11.9 bpm) (p < 0.0001). The predictive formula (HRscan = 3.601 + 0.113HRrest + 0.8HRtest) was determined to be accurate only in Group Dec. The HRtest significantly decreased from the HRrest, and the HRscan significantly decreased from the HRtest. An accurate predictive formula for HRscan could be built only for Group Dec.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AAPM / RSNA PHYSICS TUTORIAL 1495 AAPM / RSNA Physics Tuto - rial for Residents Physics of Cardiac Imaging with Multiple - Row Detector CT 1

Cardiac imaging with multiple-row detector computed tomography (CT) has become possible due to rapid advances in CT technologies. Images with high temporal and spatial resolution can be obtained with multiple-row detector CT scanners; however, the radiation dose associated with cardiac imaging is high. Understanding the physics of cardiac imaging with multiple-row detector CT scanners allows op...

متن کامل

Radiation exposure for coronary artery calcium score at prospective 320 row multi - detector computed tomography

Purpose: To date there is extensive data on the radiation dose for assessing coronary artery calcium scores (CACS) with 4-64 row multidetector MDCT. However with the advent of 320 row MDCT, the entire heart can be imaged in one beat and thus potentially reduce the radiation dose. The aim of this study was to evaluate radiation dose for CACS on low-dose prospective EKG-triggered 320 row MDCT. Ma...

متن کامل

Cancerogenesis Risks between 64 and 320 Row Detector CT for Coronary CTA Screening

OBJECTIVES This study compares cancerogenesis risks posed by the 64 row detector and the 320 row detector computed tomography scanners used during coronary computed tomography angiography (CCTA) following decennial screening guidelines. MATERIAL AND METHODS Data of the radiation absorbed after CCTA by lung, thyroid, and female breast in patients between 50 and 70 years of age obtained from pr...

متن کامل

Iodinated Contrast Opacification Gradients in Normal Coronary Arteries Imaged with Prospectively ECG-Gated Single Heart Beat 320-Detector Row Computed Tomography Steigner;Normal Coronary CT Contrast Gradients

Background: To define and evaluate coronary contrast opacification gradients using prospectively ECG-gated single heart beat 320-detector row coronary angiography (CTA). Methods and Results: Thirty-six patients with normal coronary arteries determined by 320 x 0.5 mm detector row coronary CTA were retrospectively evaluated with customized image postprocessing software to measure Hounsfield Unit...

متن کامل

Evaluation of appropriateness of second-generation 320-row computed tomography for coronary artery disease

The influence of newer-generation CT on the clinical indications and appropriateness of cardiac CT has not been adequately surveyed. We aimed to evaluate the distribution of appropriateness ratings and test the outcomes of cardiac CT using second-generation 320-row CT. The 2010 appropriate use criteria (AUC) were applied at the point of service to a consecutive series of patients (N = 309) who ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2015