Minimax Emission Computed Tomography using High-Resolution Anatomical Side Information and B-Spline Models
نویسندگان
چکیده
In this paper a minimax methodology is presented for combining information from two imaging modalities having different intrinsic spatial resolutions. The focus application is emission computed tomography (ECT), a low-resolution modality for reconstruction of radionuclide tracer density, when supplemented by high-resolution anatomical boundary information extracted from a magnetic resonance image (MRI) of the same imaging volume. The MRI boundary within the two-dimensional (2-D) slice of interest is parameterized by a closed planar curve. The Cramèr–Rao (CR) lower bound is used to analyze estimation errors for different boundary shapes. Under a spatially inhomogeneous Gibbs field model for the tracer density a representation for the minimax MRI-enhanced tracer density estimator is obtained. It is shown that the estimator is asymptotically equivalent to a penalized maximum likelihood (PML) estimator with resolutionselective Gibbs penalty. Quantitative comparisons are presented using the iterative space alternating generalized expectation maximization (SAGE-EM) algorithm to implement the PML estimator with and without minimax weight averaging.
منابع مشابه
Minimax Emission Computed Tomography Using High-resolution Anatomical Side Information And B-spline - Information Theory, IEEE Transactions on
In this paper a minimax methodology is presented for combining information from two imaging modalities having different intrinsic spatial resolutions. The focus application is emission computed tomography (ECT), a low-resolution modality for reconstruction of radionuclide tracer density, when supplemented by high-resolution anatomical boundary information extracted from a magnetic resonance ima...
متن کاملREVISION OF SUBMISSION TO IEEE TRANSACTIONS ON INFORMATION THEORY , 1998 1 Minimax Emission Computed Tomography using High ResolutionAnatomical Side
In this paper a minimax methodology is presented for combining information from two imaging modalities having diierent intrinsic spatial resolutions. The focus application is emission computed tomography (ECT), a low resolution modality for reconstruction of radionuclide tracer density, when supplemented by high resolution anatomical boundary information extracted from a magnetic resonance imag...
متن کاملTheory and Implementation of Minimax Ect Image Reconstruction with Mri Side Information
In this report a minimax methodology is presented for combining information from two imaging modalities having diierent intrinsic spatial resolutions. The focus application is emission computed tomography (ECT), a low resolution modality for reconstruction of radionuclide tracer density, when supplemented by high resolution anatomical boundary information extracted from a magnetic resonance ima...
متن کاملNoninvasive Stem Cell Labeling Using USPIO Technique and their Detection with MRI
Background: To date, several imaging techniques to track stem cells are used such as positron emission tomography (PET), single photon emission computed tomography (SPECT), Bioluminescence imaging (BLI), fluorescence imaging, CT scan and magnetic resonance imaging (MRI). Although, overall sensitivity of MRI compared to SPECT and Bioluminescence techniques are lower, but due to high spatial reso...
متن کاملMRI-PET Registration with Automated Algorithm in Pre-clinical Studies
Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) automatic 3-D registration is implemented and validated for small animal image volumes so that the high-resolution anatomical MRI information can be fused with the low spatial resolution of functional PET information for the localization of lesion that is currently in high demand in the study of tumor of cancer (oncology) a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- IEEE Trans. Information Theory
دوره 45 شماره
صفحات -
تاریخ انتشار 1999