The accuracy of 'power' maps to display curvature data in corneal topography systems.
نویسنده
چکیده
PURPOSE To quantify the error introduced by videokeratographic corneal topography devices in using a paraxial formula to calculate power over the entire corneal surface, including areas removed from the central paraxial region where the formula is known to be invalid. METHODS Corneal refractive power and two paraxial power approximations were computed as a function of distance from the apex for three theoretical surfaces, a sphere and two ellipsoids with 0.3 and 0.5 eccentricities. Color dioptric maps were then theoretically created. RESULTS For the spherical surface, both curvature-based paraxial power approximations were uniform over the entire surface because curvature is constant. However, the corneal refractive power increased from center to periphery, demonstrating the known phenomenon of spherical aberration. For the ellipsoids, which have been shown to model the human cornea, curvature-based power approximations decreased from center to periphery because the curvature flattens peripherally. However, refractive power increased from center to periphery. The limits of the central paraxial region for these surfaces was shown to be approximately 2 mm in diameter for the paraxial power approximation used by videokeratographic devices to measure 8 mm in diameter. CONCLUSIONS The direct correlation between corneal curvature and power with which clinicians are familiar is not valid in the peripheral regions measured by videokeratographic devices. Topographic devices measure curvature, which should not be interpreted as corneal power except in the central region. A recommendation to device manufacturers is to display "color curvature maps" instead of color dioptric maps, and to label the color bar with curvature values instead of power.
منابع مشابه
The Accuracy of Tower' Maps to Display Curvature Data in Corneal Topography Systems
Results. For the spherical surface, both curvature-based paraxial power approximations were uniform over the entire surface because curvature is constant. However, the corneal refractive power increased from center to periphery, demonstrating the known phenomenon of spherical aberration. For the ellipsoids, which have been shown to model the human cornea, curvature-based power approximations de...
متن کاملبررسی اثر قطره هوماتروپین 2% بر روی توپوگرافی قرنیه
ABSTRACT The purpose of this study was the evaluation of cycloplegic effect of homatropine 2% on central corneal curvature and power. 43 volunteers who participated in the study were examined. Thirty-nine of them (28 men and 11 women) which had normal eyes with visual acuity of 20/20 and a mean age of 29.6 ± 6.7 years were selected. Then corneal topography was performed on both eyes. After per...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملEvaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system.
AIMS To map the thickness, elevation (anterior and posterior corneal surface), and axial curvature of the cornea in normal eyes with the Orbscan corneal topography system. METHODS 94 eyes of 51 normal subjects were investigated using the Orbscan corneal topography system. The anterior and posterior corneal elevation maps were classified into regular ridge, irregular ridge, incomplete ridge, i...
متن کاملInvestigation of corneal topography after deep lamellar endothelial keratoplasty.
PURPOSE To analyze the 6-month anterior and posterior topographic changes of the cornea after deep lamellar endothelial keratoplasty. METHODS Orbscan topographies of 22 eyes from 21 patients with corneal decompensation were retrospectively analyzed: 11 eyes received a 9-mm scleral access incision (large-incision group) and 11 eyes received a 5-mm scleral access incision (small-incision group)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 35 9 شماره
صفحات -
تاریخ انتشار 1994