Male Breast Cancer-Dosimetry Evaluation in Teletherapy
نویسندگان
چکیده
The rate of male breast cancer has increased in recent years, due to the deficiency of preventive examinations (male mammography). Besides, since male breasts are generally smaller than female breasts, it is essential to monitor the doses received by male breasts, as well as those received by close, healthy and critical organs in order to assess the plan used in this kind of treatment. To do this, the distribution of doses in male breasts was simulated and assessed, based on the procedures adopted in the treatment of female breasts, when submitted to a radiation beam from a linear accelerator. The Alderson Rando phantom was used and the relevant absorbed doses were measured by TLD-100 thermoluminescent dosimeters distributed throughout the volume of interest. The results of the treatment planning were compared with the results obtained by TLDs. A difference of up to 8.5%, in comparison with the planned dose, as well as a 6% relative standard deviation was found.
منابع مشابه
Verification of the Accuracy of the Delivered Dose in Pelvic and Breast Cancer Radiotherapy by in-vivo Semi-Conductor Dosimetry
Introduction: Delivering maximum dose to tumor and minimum dose to normal tissues is the most important goal in radiotherapy. According to ICRU, the maximum acceptable uncertainty in the delivered dose compared to the prescribed dose should be lower than 5%, and this is because of the relationship between absorbed dose, tumor control and normal tissue damage. Absorbed dose accuracy is investiga...
متن کاملEvaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry
Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...
متن کاملDosimetric Conformity of Cobalt-60 (Co) Beams
Objective: The radiation dosimetry is the output measurement of radiation generating source/ machine and its ambition is to ensure that the teletherapy units’ outputs are within limits. In the current article, the dosimetry of Cobalt-60 (Co 60 ) teletherapy units at Nuclear Institute of Medicine and Radiotherapy (NIMRA), Jamshoro Pakistan was studied. As Co 60 is undergo decay process, the outp...
متن کاملThe Effect of Breast Phantom Material on the Dose Distribution in AccuBoost Brachytherapy
Introduction: Long-term teletherapy program is not suitable for old and working patients and those living in areas where little access to primary health care is available. Accelerated partial breast irradiation (APBI) using high dose rate (HDR) brachytherapy is an appropriate alternative for these patients due to its limited number of fractions. The AccuBoost is a system for delivering APBI. Th...
متن کاملDosimetric Consistency of Co-60 Teletherapy Unit- a ten years Study.
OBJECTIVE The goal of the Radiation standards and Dosimetry is to ensure that the output of the Teletherapy Unit is within ±2% of the stated one and the output of the treatment dose calculation methods are within ±5%. In the present paper, we studied the dosimetry of Cobalt-60 (Co-60) Teletherapy unit at Sher-I-Kashmir Institute of Medical Sciences (SKIMS) for last 10 years. Radioactivity is th...
متن کامل