Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves.
نویسندگان
چکیده
BACKGROUND The majority of prosthetic heart valves currently implanted are tissue valves that can be expected to degenerate with time and eventually fail. Repeat cardiac surgery to replace these valves is associated with significant morbidity and mortality. Transcatheter heart valve implantation within a failed bioprosthesis, a "valve-in-valve" procedure, may offer a less invasive alternative. METHODS AND RESULTS Valve-in-valve implantations were performed in 24 high-risk patients. Failed valves were aortic (n=10), mitral (n=7), pulmonary (n=6), or tricuspid (n=1) bioprostheses. Implantation was successful with immediate restoration of satisfactory valve function in all but 1 patient. No patient had more than mild regurgitation after implantation. No patients died during the procedure. Thirty-day mortality was 4.2%. Mortality was related primarily to learning-curve issues early in this high-risk experience. At baseline, 88% of patients were in New York Heart Association functional class III or IV; at the last follow-up, 88% of patients were in class I or II. At a median follow-up of 135 days (interquartile range, 46 to 254 days) and a maximum follow-up of 1045 days, 91.7% of patients remained alive with satisfactory valve function. CONCLUSIONS Transcatheter valve-in-valve implantation is a reproducible option for the management of bioprosthetic valve failure. Aortic, pulmonary, mitral, and tricuspid tissue valves were amenable to this approach. This finding may have important implications with regard to valve replacement in high-risk patients.
منابع مشابه
Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)
Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...
متن کاملTranscatheter aortic valve-in-valve implantation for patients with degenerative surgical bioprosthetic valves.
Most surgical heart valves currently implanted are bioprosthetic tissue valves. Such valves deteriorate with time, eventually presenting with either stenosis or regurgitation. Reoperation, the current standard of care for failed valves, carries significant risk in terms of both morbidity and mortality. Implantation of a transcatheter valve inside a failed surgical valve (valve-in-valve procedur...
متن کاملTranscatheter valve-in-valve implantation for failed surgical bioprosthetic valves.
When bioprosthetic cardiac valves fail, reoperative valve replacement carries a higher risk of morbidity and mortality compared with initial valve replacement. Transcatheter heart valve implantation may be a viable alternative to surgical aortic valve replacement for high-risk patients with native aortic stenosis, and valve-in-valve (V-in-V) implantation has been successfully performed for fail...
متن کاملAortic Valve Replacement in Children and Young Adults.
SEE PAGE 2858 T he perfect heart valve substitute has not yet been developed and matching the patient to existing options to optimize survival and reduce valve-related complications remains challenging. The choices for aortic valve replacement (AVR) are mechanical valves, bioprosthetic valves, and biological valves such as aortic valve homograft and the Ross procedure (pulmonary autograft). The...
متن کاملTranscatheter heart valve in valve implantation with Edwards SAPIEN bioprosthetic valve for different degenerated bioprosthetic valve positions (First Iranian ViV report with mid-term follow up)
Introduction: After early successful experience with transcatheter aortic valve replacement (TAVR), concept of transcatheter implantation of a new valve within a failing bioprosthetic valve emerged. Valve-in-valve (ViV) implantation seems to be a simpler option for high risk surgical patients. Methods: We performed five ViV procedures in different valve positions. We included patients with fail...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 121 16 شماره
صفحات -