Radiation intensity (CTDIvol) and visibility of anatomical structures in head CT examinations
نویسندگان
چکیده
The purpose of this study was to quantify how changing the amount of radiation used to perform routine head CT examinations (CTDIvol) affects visibility of key anatomical structures. Eight routine noncontrast head CT exams were selected from six CT scanners, each of which had a different CTDIvol setting (60 to 75 mGy). All exams were normal and two slices were selected for evaluation, one at the level of basal ganglia and the other at the fourth ventricle. Three experienced neuroradiologists evaluated the visibility of selected structures, including the putamen, caudate nucleus, thalamus, internal capsule, grey/white differentiation, and brainstem. Images were scored on a five-point scoring scheme (1, unacceptable, 3, satisfactory, and 5, excellent). Reader scores, averaged over the cases obtained from each scanner, were plotted as a function of the corresponding CTDIvol. Average scores for the fourth ventricle were 3.06 ± 0.83 and for the basal ganglia were 3.20 ± 0.86. No image received a score of 1. Two readers showed no clear trend of an increasing score with increasing CTDIvol. One reader showed a slight trend of increasing score with increasing CTDIvol, but the increase in score from a 25% increase in CTDIvol was a fraction of the standard deviation associated average scores. Collectively, results indicated that there were no clear improvements in visualizing neuroanatomy when CTDIvol increased from 60 to 75 mGy in routine head CT examinations. Our study showed no apparent benefit of using more than 60 mGy when performing routine noncontrast head CT examinations.
منابع مشابه
Assessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels
Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملEstablishment of CT diagnostic reference levels in select procedures in South India
Background: To suggest South India CT diagnostic reference levels (DRLs) by collecting radiation doses for the most commonly performed CT examinations. Materials and Methods: A pilot study investigated the most frequent CT examinations. 110 CT sites were asked to complete a survey booklet to allow the recording of CT parameters for each of 3 CT examinations during a 1 year time period. Dose...
متن کاملEstimation of Mean Patient Dose Indices in Chest and Abdomen/Pelvis CT Examinations in Rafsanjan Ali Ibn Abitalib Hospital in 2018: A Descriptive Study
Background and Objectives: The radiation protection of patients in CT examinations is important due to its wide application and high contribution in collective dose of public, and its radiation effects. The purpose of this study was to estimate the mean patient dose indices in chest and abdomen/pelvic examinations as the first step in patient radiation protection process. Materials and Methods...
متن کاملImage Optimization and reduction of radiation dose in CT of the paranasal sinuses
Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...
متن کامل