Do stand-alone interbody spacers with integrated screws provide adequate segmental stability for multilevel cervical arthrodesis?
نویسندگان
چکیده
BACKGROUND CONTEXT Some postoperative complications after anterior cervical fusions have been attributed to anterior cervical plate (ACP) profiles and the necessary wide operative exposure for their insertion. Consequently, low-profile stand-alone interbody spacers with integrated screws (SIS) have been developed. Although SIS constructs have demonstrated similar biomechanical stability to the ACP in single-level fusions, their role as a stand-alone device in multilevel reconstructions has not been thoroughly evaluated. PURPOSE To evaluate the acute segmental stability afforded by an SIS device compared with the traditional ACP in the setting of a multilevel cervical arthrodesis. STUDY DESIGN In vitro human cadaveric biomechanical analysis. METHODS Thirteen human cadaveric cervical spines (C2-T1) were nondestructively tested with a custom 6 df spine simulator under axial rotation, flexion-extension, and lateral bending loading. After intact analysis, eight single-levels (C4-C5/C6-C7) from four specimens were instrumented and tested with ACP and SIS. Nine specimens were tested with C5-C7 SIS, C5-C7 ACP, C4-C7 ACP, C4-C7 ACP+posterior fixation, C4-C7 SIS, and C4-C7 SIS+posterior fixation. Testing order was randomized with each additional level instrumented. Full range of motion (ROM) data were obtained and analyzed by each loading modality, using mean comparisons with repeated measures analysis of variance. Paired t tests were used for post hoc analysis with Sidak correction for multiple comparisons. RESULTS No significant difference in ROM was noted between the ACP and SIS for single-level fixation (p>.05). For multisegment reconstructions (two and three levels), the ACP proved superior to SIS and intact condition, with significantly lower ROM in all planes (p<.05). When either the three-level SIS or ACP constructs were supplemented with posterior lateral mass fixation, there was a greater than 80% reduction in ROM under all testing modalities (p<.05), with no significant difference between the ACP and SIS constructs (p>.05). CONCLUSIONS The SIS device may be a reasonable option as a stand-alone device for single-level fixation. However, SIS devices should be used with careful consideration in the setting of multilevel cervical fusion. However, when supplemented with posterior fixation, SIS devices are a sound biomechanical alternative to ACP for multilevel fusion constructs.
منابع مشابه
Evaluation of Two Novel Integrated Stand-Alone Spacer Designs Compared with Anterior and Anterior-Posterior Single-Level Lumbar Fusion Techniques: An In Vitro Biomechanical Investigation
Study Design In vitro biomechanical investigation. Purpose To compare the biomechanics of integrated three-screw and four-screw anterior interbody spacer devices and traditional techniques for treatment of degenerative disc disease. Overview of Literature Biomechanical literature describes investigations of operative techniques and integrated devices with four dual-stacked, diverging interb...
متن کاملBiomechanical evaluation of stand-alone interbody fusion cages in the cervical spine.
STUDY DESIGN An in vitro biomechanical investigation of the immediate stability in cervical reconstruction. OBJECTIVES The purpose of this study was to compare the segmental stability afforded by the interbody fusion cage, the anterior locking plate, and the "gold standard" autograft. SUMMARY OF BACKGROUND DATA Recently, interbody fusion cage devices have been developed and used for cervica...
متن کاملUnilateral Minimally Invasive Posterior Lumbar Interbody Fusion (Unilateral Micro-PLIF) for Degenerative Spondylolisthesis: Surgical Technique
Degenerative spondylolisthesis has long been recognized as a cause of chronic low back pain and sciatica. Extensive anatonmical and embryological studies have not fully explained the cause of this painful condition. The mechanism of pain in degenerative spondylolisthesis has been confirmed by demonstrating the disc lesion pre-operatively by X-rays and MR imaging followed by surgical treatment i...
متن کاملBiomechanical Evaluation of a Standalone Lumbar Interbody Cage with Integrated Screws
INTRODUCTION: Spinal fusion techniques including anterior lumbar interbody fusion (ALIF) have been used to alleviate chronic low back pain and segmental instability. Supplemental fixation using pedicle screws, translaminar screws, facet screws, anterior plates or spinous process plates is often used to increase the stability of the ALIF construct to enhance fusion and prevent subsidence and mig...
متن کاملDo translaminar facet screws have the same stability as pedicle screws in two-level anterior lumbar interbody fusion? A biomechanical study.
AIM To determine whether translaminar facet screws can provide stability equivalent to pedicle screws in two-level anterior lumbar interbody fusion. MATERIAL AND METHODS We performed a biomechanical study using 12 fresh human lumbar spines and tested intact spine, stand-alone two-level ALIF and anterior fusion augmented with pedicle screws or translaminar facet screws under 400N ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The spine journal : official journal of the North American Spine Society
دوره 14 8 شماره
صفحات -
تاریخ انتشار 2014