Rapid Quantitative Evaluation of Amphotericin B in Human Plasma, by Validated HPLC Method

نویسندگان

  • Pavan Balabathula
  • Dileep R Janagam
  • Nivesh K Mittal
  • Bivash Mandal
  • Laura A Thoma
چکیده

A simple, rapid, and sensitive HPLC method was developed and validated to quantify Amphotericin B (AmB) in human plasma. AmB was extracted from spiked plasma by simple protein precipitation with methanol. The separation was performed on an XBridgeTM C18 (150 × 4.6 mm, 3.5 μm) column, with a mobile phase of acetic acid (0.73%) – acetonitrile (60:40, v/v) and at a flow rate of 1 mL/min. The eluted peak of AmB was monitored at 408 nm with photo-diode array detector (PDA) detector. The calibration curve was found linear in the AmB concentration range of 1000 – 50 ng/mL (r2>0.99). The interand intra-day precisions (%CV) were less than 11.2%. The extraction recoveries were 85-91%. The method developed and validated is simple, rapid (<3 min per injection), sensitive, and reproducible. It potentially can be used for the pharmacokinetic, bioequivalence, and toxicokinetic studies of AmB. Rapid Quantitative Evaluation of Amphotericin B in Human Plasma, by Validated HPLC Method

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Determination of mirtazapine and desmethyl mirtazapine in human plasma by a new validated HPLC ultraviolet method with a simple and reliable extraction method: Application to therapeutic drug monitoring study by 62 real patient plasma

Determination of mirtazapine during psychopharmacotherapy in biological fluids is essential to achieve successful therapy, to avoid toxicity related to drug interactions, genetic variability and poor compliance. A new, rapid and sensitive high-performance liquid chromatography method has been developed in human plasma for the determination of mirtazapine (MRP) and N-desmethylmirtazapine (NDM) t...

متن کامل

Determination of mirtazapine and desmethyl mirtazapine in human plasma by a new validated HPLC ultraviolet method with a simple and reliable extraction method: Application to therapeutic drug monitoring study by 62 real patient plasma

Determination of mirtazapine during psychopharmacotherapy in biological fluids is essential to achieve successful therapy, to avoid toxicity related to drug interactions, genetic variability and poor compliance. A new, rapid and sensitive high-performance liquid chromatography method has been developed in human plasma for the determination of mirtazapine (MRP) and N-desmethylmirtazapine (NDM) t...

متن کامل

Simple and sensitive high performance liquid chromatographic method for the simultaneous quantitation of the phenylalanine in human plasma

Phenylalanine (Phe) is the most reliable indicator for the diagnosis of phenylketonuria (PKU). The purpose of this study is to establish a reliable and quick method for the assignment of Phe in peripheral capillary blood from newborns and children by high performance liquid chromatography with ultraviolet detection (HPLC-UV). PKU is an inborn error of metabolism characterized by the inability o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013