Evaluation of droplet dispersion during non-invasive ventilation, oxygen therapy, nebuliser treatment and chest physiotherapy in clinical practice: implications for management of pandemic influenza and other airborne infections.

نویسندگان

  • A K Simonds
  • A Hanak
  • M Chatwin
  • Mj Morrell
  • A Hall
  • K H Parker
  • J H Siggers
  • R J Dickinson
چکیده

BACKGROUND Influenza viruses are thought to be spread by droplets, but the role of aerosol dissemination is unclear and has not been assessed by previous studies. Oxygen therapy, nebulised medication and ventilatory support are treatments used in clinical practice to treat influenzal infection are thought to generate droplets or aerosols. OBJECTIVES Evaluation of the characteristics of droplet/aerosol dispersion around delivery systems during non-invasive ventilation (NIV), oxygen therapy, nebuliser treatment and chest physiotherapy by measuring droplet size, geographical distribution of droplets, decay in droplets over time after the interventions were discontinued. METHODS Three groups were studied: (1) normal controls, (2) subjects with coryzal symptoms and (3) adult patients with chronic lung disease who were admitted to hospital with an infective exacerbation. Each group received oxygen therapy, NIV using a vented mask system and a modified circuit with non-vented mask and exhalation filter, and nebulised saline. The patient group had a period of standardised chest physiotherapy treatment. Droplet counts in mean diameter size ranges from 0.3 to > 10 µm were measured with an counter placed adjacent to the face and at a 1-m distance from the subject/patient, at the height of the nose/mouth of an average health-care worker. RESULTS NIV using a vented mask produced droplets in the large size range (> 10 µm) in patients (p = 0.042) and coryzal subjects (p = 0.044) compared with baseline values, but not in normal controls (p = 0.379), but this increase in large droplets was not seen using the NIV circuit modification. Chest physiotherapy produced droplets predominantly of > 10 µm (p = 0.003), which, as with NIV droplet count in the patients, had fallen significantly by 1 m. Oxygen therapy did not increase droplet count in any size range. Nebulised saline delivered droplets in the small- and medium-size aerosol/droplet range, but did not increase large-size droplet count. CONCLUSIONS NIV and chest physiotherapy are droplet (not aerosol)-generating procedures, producing droplets of > 10 µm in size. Due to their large mass, most fall out on to local surfaces within 1 m. The only device producing an aerosol was the nebuliser and the output profile is consistent with nebuliser characteristics rather than dissemination of large droplets from patients. These findings suggest that health-care workers providing NIV and chest physiotherapy, working within 1 m of an infected patient should have a higher level of respiratory protection, but that infection control measures designed to limit aerosol spread may have less relevance for these procedures. These results may have infection control implications for other airborne infections, such as severe acute respiratory syndrome and tuberculosis, as well as for pandemic influenza infection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Chest Physical Therapy Effect on Full Term Neonates with Primary Pneumonia: A Clinical Trial Study

Background Chest physiotherapy has been used to clear secretions in pediatrics for many respiratory problems. The aim of this study was to investigate the effect of chest physical therapy on full term neonates with primary pneumonia. Materials and Methods Sixty full term neonates admitted to  neonatal intensive care unit (NICU), Minia University, Egypt, during the period from September 2016 to...

متن کامل

New modalities for non-invasive positive pressure ventilation: A review article

Efficiency of non-invasive positive pressure ventilation in the treatment of respiratory failure has been shown in many published studies. In this review article, we introduced new modalities of non-invasive ventilation (NIV), clinical settings in which NIV can be used and a practical summary of the latest official guidelines published by the European Respiratory Clinical Practice. Clinical tri...

متن کامل

Tilt Table Practice Improved Ventilation in a Patient with Prolonged Artificial Ventilation Support in Intensive Care Unit

Patients who are on prolonged ventilator support in critical care unit present wide variety of complications, which range from reduction in oxygen uptake to various musculoskeletal impair-ments. Early mobilization and rehabilitation are encouraged to manage these complications effectively. Use of tilt table to motivate early mobilization in the intensive care unit for ventilator practices is no...

متن کامل

CYSTIC FIBROSIS Non-invasive ventilation assists chest physiotherapy in adults with acute exacerbations of cystic fibrosis

Background: Chest physiotherapy is essential to the management of cystic fibrosis (CF). However, respiratory muscle fatigue and oxygen desaturation during treatment have been reported. The aim of this study was to determine whether non-invasive ventilation (NIV) during chest physiotherapy could prevent these adverse effects in adults with exacerbations of CF. Methods: Twenty six patients of mea...

متن کامل

Efficiency and outcome of non-invasive versus invasive positive pressure ventilation therapy in respiratory failure due to chronic obstructive pulmonary disease

Background: Application noninvasive ventilation in the patients with exacerbation of chronic obstructive pulmonary disease (COPD) reduced mortality. This case-control study was designed to compare efficiency and outcome of non-invasive (NIV) versus invasive positive pressure ventilation (IPPV) in respiratory failure due to COPD Methods: The patients were assigned to NIV or IPPV intermittantl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Health technology assessment

دوره 14 46  شماره 

صفحات  -

تاریخ انتشار 2010