POCS-enhanced correction of motion artifacts in parallel MRI.

نویسندگان

  • Alexey A Samsonov
  • Julia Velikina
  • Youngkyoo Jung
  • Eugene G Kholmovski
  • Chris R Johnson
  • Walter F Block
چکیده

A new method for correction of MRI motion artifacts induced by corrupted k-space data, acquired by multiple receiver coils such as phased arrays, is presented. In our approach, a projections onto convex sets (POCS)-based method for reconstruction of sensitivity encoded MRI data (POCSENSE) is employed to identify corrupted k-space samples. After the erroneous data are discarded from the dataset, the artifact-free images are restored from the remaining data using coil sensitivity profiles. The error detection and data restoration are based on informational redundancy of phased-array data and may be applied to full and reduced datasets. An important advantage of the new POCS-based method is that, in addition to multicoil data redundancy, it can use a priori known properties about the imaged object for improved MR image artifact correction. The use of such information was shown to improve significantly k-space error detection and image artifact correction. The method was validated on data corrupted by simulated and real motion such as head motion and pulsatile flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

POCS-Enhanced Parallel MRI Correction of MR Image Artifacts

A. Samsonov, E. Kholmovski, C. Johnson Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, United States, Department of Radiology, University of Wisconsin, Madison, Wisconsin, United States, UCAIR, University of Utah, Salt Lake City, Utah, United States, Scientific Computing and Imaging Institute, University of Utah, University of Utah, Salt Lake City, Utah, United State...

متن کامل

POCS-based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): A general algorithm for reducing motion-related artifacts.

PURPOSE A projection onto convex sets reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE) is developed to reduce motion-related artifacts, including respiration artifacts in abdominal imaging and aliasing artifacts in interleaved diffusion-weighted imaging. THEORY Images with reduced artifacts are reconstructed with an iterative projection onto convex sets (POCS) procedure that u...

متن کامل

اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدل‌سازی منحنی چند جمله ای

Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...

متن کامل

Motion compensated reconstruction for free breathing dynamic constrast-enhanced MRI

INTRODUCTION: In contrast-enhanced MRI, medical diagnosis is often compromised by the motion, the need for registration and the difficulty of sustaining a breath-hold. A previously published motion correction algorithm GRICS (Generalized Reconstruction by Inversion of Coupled Systems) [1] has proven to correct for motion artefacts successfully in images acquired with a wide set of sequences, th...

متن کامل

Efficacy of the projection onto convex sets (POCS) algorithm at Gd-EOB-DTPA-enhanced hepatobiliary-phase hepatic MRI

PURPOSE To investigate the efficacy of the projection onto convex sets (POCS) algorithm at Gd-EOB-DTPA-enhanced hepatobiliary-phase MRI. METHODS In phantom study, we scanned a phantom and obtained images by conventional means (P1 images), by partial-Fourier image reconstruction (PF, P2 images) and by PF with the POCS algorithm (P3 images). Then we acquired and compared subtraction images (P2-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 63 4  شماره 

صفحات  -

تاریخ انتشار 2010