A Biomechanical Stability Study of Extraforaminal Lumbar Interbody Fusion on the Cadaveric Lumbar Spine Specimens

نویسندگان

  • Song Guo
  • Cheng Zeng
  • Meijun Yan
  • Yingchao Han
  • Dongdong Xia
  • Guixin Sun
  • Lijun Li
  • Mingjie Yang
  • Jun Tan
چکیده

BACKGROUND Transforaminal lumbar interbody fusion (TLIF) is an effective surgery for lumbar degenerative disease. However, this fusion technique requires resection of inferior facet joint to provide access for superior facet joint resection, which results in reduced lumbar spinal stability and unnecessary trauma. We have previously developed extraforaminal lumbar interbody fusion (ELIF) that can avoid back muscle injury with direct nerve root decompression. This study aims to show that ELIF enhances lumbar spinal stability in comparison to TLIF by comparing lumbar spinal stability of L4-L5 range of motion (ROM) on 12 cadaveric spine specimens after performing TLIF or ELIF. METHODS 12 cadaveric spine specimens were randomly divided and treated in accordance with the different internal fixations, including ELIF with a unilateral pedicle screw (ELIF+UPS), TLIF with a unilateral pedicle screw (TLIF+UPS), TLIF with a bilateral pedicle screw (TLIF+BPS), ELIF with a unilateral pedicle screw and translaminar facet screw (ELIF+UPS+TLFS) and ELIF with a bilateral pedicle screw (ELIF+BPS). The treatment groups were exposed to a 400-N load and 6 N·m movement force to calculate the angular displacement of L4-L5 during anterior flexion, posterior extension, lateral flexion and rotation operation conditions. RESULTS The ROM in ELIF+UPS group was smaller than that of TLIF+UPS group under all operating conditions, with the significant differences in left lateral flexion and right rotation by 36.15% and 25.97% respectively. The ROM in ELIF+UPS group was higher than that in TLIF+BPS group. The ROM in the ELIF+UPS+TLFS group was much smaller than that in the ELIF+UPS group, but was not significantly different than that in the TLIF+BPS group. CONCLUSIONS Despite that TLIF+BPS has great stability, which can be comparable by that of ELIF+UPS. Additionally, ELIF stability can be further improved by using translaminar facet screws without causing more tissue damage to patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Digitalized Design of Extraforaminal Lumbar Interbody Fusion: A Computer-Based Simulation and Cadaveric Study

PURPOSE This study aims to investigate the feasibility of a novel lumbar approach named extraforaminal lumbar interbody fusion (ELIF), a newly emerging minimally invasive technique for treating degenerative lumbar disorders, using a digitalized simulation and a cadaveric study. METHODS The ELIF surgical procedure was simulated using the Mimics surgical simulator and included dissection of the...

متن کامل

Comparison of Supplementary Posterior Fixations for Two-Level ALIF with Stand-Alone Cages

INTRODUCTION: Structural cages have been widely used in recent years to maintain motion segment height and stability in anterior lumbar interbody fusion (ALIF). High rate of clinical success and radiological fusion rate have been reported following single-level fusion using these cages. However, many biomechanical studies report insufficient stability, especially with extension loading. Posteri...

متن کامل

Biomechanics of lateral plate and pedicle screw constructs in lumbar spines instrumented at two levels with laterally placed interbody cages.

BACKGROUND CONTEXT The lateral transpsoas approach to interbody fusion is gaining popularity because of its minimally invasive nature and resultant indirect neurologic decompression. The acute biomechanical stability of the lateral approach to interbody fusion is dependent on the type of supplemental internal fixation used. The two-hole lateral plate (LP) has been approved for clinical use for ...

متن کامل

THE EFFECTS OF ANTERIOR DISCECTOMY AND INTERPOSITION AL IMPLANT UPON LUMBAR MOTION SEGMENT STABILITY

The cadaver spine motion segment behavior under torsional load was evaluated with the disc intact, with partial anterior discectomy and with spacer insertion. The results of this study explain how anterior lumbar discectomy and interbody fusion (ALIF) affects the torsional stability of the motion segment. The pseudarthrosis rate of the anterior lumbar discectomy and interbody fusion (ALIF)...

متن کامل

A Biomechanical Comparison of Shape Design and Positioning of Transforaminal Lumbar Interbody Fusion Cages

STUDY DESIGN Cadaveric biomechanical analysis. OBJECTIVE The aim of this study was to compare three interbody cage shapes and their position within the interbody space with regards to construct stability for transforaminal lumbar interbody fusion. METHODS Twenty L2-L3 and L4-L5 lumbar motion segments from fresh cadavers were potted in polymethyl methacrylate and subjected to testing with a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016