Kinetic centrifugal analyzer and manual determination of serum urea nitrogen, with use of o-phthaldialdehyde reagent.
نویسنده
چکیده
o-Phthaldialdehdye reagent was used in assaying urea with a miniature centrifugal analyzer. Seventeen samples can be assayed kinetically in 2 min at a current cost of less than a penny per test. The reaction is initiated in the instrument upon simultaneous mixing of the o-phthaldialdehyde reagent containing 10 microliter of sample with dilute sulfuric acid/N-(1-naphthyl)ethylenediamine dihydrochloride reagent. The reaction is monitored kinetically at 546 nm during the initial 2 min, when the rate is nearly constant. The reaction of o-phthaldialdehyde with urea reaches equilibrium by about 7 or 8 min, but the method cannot be used for end-point analysis because of interference by the blank reaction. A 1.2 g/liter solution of o-phthaldialdehyde used in conjunction with 2 mol/liter sulfuric acid solution was found to be most suitable for centrifugal analyzers. I also describe a manual version of the procedure that gives a linear standard curve up to 1.0 g of urea nitrogen per liter.
منابع مشابه
An integrated approach to lipid profiling: enzymatic determination of cholesterol and triglycerides with a centrifugal analyzer.
We describe enzymatic methods for determination of cholesterol and triglycerides (triacylglycerols), adapted for use with a centrifugal analyzer. Triglycerides are determined by a two-point kinetic method, which utilizes a single glycerol standard for calibration and provides for a within-run reagent blank correction. The endpoint determination of cholesterol combines the unique blanking capabi...
متن کاملStability in urea as a measure of cardiac lactate dehydrogenase on the centrifugal analyzer.
Kinetic methods are described for determination of total, heat-stable, and urea-stable lactate dehydrogenase (EC 1.1.1.27) activity on the centrifugal analyzer. In the urea-stable method we present, 2.6 molar urea is used to differentiate lactate dehydrogenase originatingfrom heart and liver.This urea concentration, greater than that used by most other investigators, better differentiates betwe...
متن کاملManual and centrifugal analyzer determination of cholesterol and triglycerides with single-vial enzymatic reagents.
We have assessed Calbiochem single-vial enzymatic reagent systems for the analysis for cholesterol and triglycerides, using manual and centrifugal analyzer techniques. Analysis for cholesterol by both techniques had acceptable performance by the short-term criteria of the Center for Disease Control (CDC) during this study carried out under optimal conditions of variance. Analysis for triglyceri...
متن کاملFour commercial urease reagents and a laboratory-prepared reagent compared for analysis of blood urea nitrogen with the Beckman analyzer.
Three laboratory-prepared urease reagents were compared with a commercial preparation supplied for routine use on the Beckman Blood Urea Nitrogen Analyzer. There were discrepancies in results for urea nitrogen among the four urease reagents when matching serum and the corresponding oxalate/fluoride treated plasma were compared as measured with the Beckman Analyzer and continuous-flow (AutoAnaly...
متن کاملMeasurement of total protein and albumin in serum with a centrifugal analyzer.
In most clinical chemistry laboratories, mechanized procedures are essential for measurement of serum total protein and albumin. The biuret reaction is well established as the most practical approach to mechanized total protein measurements (1-4); albumin has posed a more difficult problem, with several procedures being proposed, some of which have involved salt fractionation (1-4), electrophor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 24 12 شماره
صفحات -
تاریخ انتشار 1978