A Novel Robust Tube Detection Filter for 3D Centerline Extraction
نویسندگان
چکیده
Centerline extraction of tubular structures such as blood vessels and airways in 3D volume data is of vital interest for applications involving registration, segmentation and surgical planing. In this paper, we propose a robust method for 3D centerline extraction of tubular structures. The method is based on a novel multiscale medialness function and additionally provides an accurate estimate of tubular radius. In contrast to other approaches, the method does not need any user selected thresholds and provides a high degree of robustness. For comparison and performance evaluation, we are using both synthetic images from a public database and a liver CT data set. Results show the advantages of the proposed method compared with the methods of Frangi et al. and Krissian et al.
منابع مشابه
Magisterarbeit Robust Segmentation of Tubular Structures in 3D Volume Data
Segmentation of tubular structures like blood vessels and airways in 3D volume data is of vital interest for medical applications like diagnosis and surgical planning. The aim of this diploma thesis is to facilitate the efficient analysis of vessels by developing an automatic segmentation method. First, the method uses a vessel detection filter, which is based on a novel multiscale medialness f...
متن کاملISSN 1392–124X (print), ISSN 2335–884X (online) INFORMATION TECHNOLOGY AND CONTROL
This paper presents a new automatic 3D mesh-based centerline extraction (3D-MCE) algorithm, which allows an accurate extraction of 3D centerline from a tubular geometry form, without manned intervention. The 3DMCE does not require any input parameters and works on polygon mesh vertices producing a thin, connected and centered centerline, without needing pre or post-processing stages. In order t...
متن کاملA Robust Level-Set Algorithm for Centerline Extraction
We present a robust method for extracting 3D centerlines from volumetric datasets. We start from a 2D skeletonization method to locate voxels centered with respect to three orthogonal slicing directions. Next, we introduce a new detection criterion to extract the centerline voxels from the above skeletons, followed by a thinning, reconnection, and a ranking step. Overall, the proposed method pr...
متن کامل3D Geometric Analysis of Tubular Objects Based on Surface Normal Accumulation
This paper proposes a simple and efficient method for the reconstruction and extraction of geometric parameters from 3D tubular objects. Our method constructs an image that accumulates surface normal information, then peaks within this image are located by tracking. Finally, the positions of these are optimized to lie precisely on the tubular shape centerline. This method is very versatile, and...
متن کاملA New Tube Detection Filter for Abdominal Aortic Aneurysms
Tube detection filters (TDFs) are useful for segmentation and centerline extraction of tubular structures such as blood vessels and airways in medical images. Most TDFs assume that the cross-sectional profile of the tubular structure is circular. This assumption is not always correct, for instance in the case of abdominal aortic aneurysms (AAAs). Another problem with several TDFs is that they g...
متن کامل