Use of an ac heterodyne lateral shear interferometer with real-time wavefront correction systems.
نویسنده
چکیده
An analysis is performed to determine the accuracy with which an ac heterodyne lateral shear interferometer can measure wavefront aberrations if a white light extended source is used with the interferometer, and shot noise is the predominate noise source. The analysis shows that for uniform circular or square sources larger than a derived minimum size, the wavefront measurement accuracy depends only upon the radiance of the source and not upon the angular subtense of the source. For a 1-msec integration time, a 25-cm(2) collecting area, and a source radiance of 10 W/m(2)-sr the rms wavefront error is approximately 1/30 wave, assuming the signal is shot noise limited. It is shown that for both uniform circular and square sources an optimum shear distance is approximately (1/2) the aperture diameter required to resolve the light source. Comments are made on the optimum shear for nonuniform radiance distributions.
منابع مشابه
Double frequency grating lateral shear interferometer.
A simple grating lateral shear interferometer is described that can be made to give simultaneously two interferograms having shear in two orthogonal directions. The shear for the two orthogonal directions is produced in one plane by one double frequency crossed diffraction grating that can easily be produced holographically. Translating the grating sideways causes the irradiance of the interfer...
متن کاملError Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer
A new heterodyne nano-displacement with error reduction is presented. The main errors affecting the displacement accuracy of the nano-displacement measurement system including intermodulation distortion error, cross-talk error, cross-polarization error and phase detection error are calculated. In the designed system, a He-Ne laser having three-longitudinal-mode is considered as the stabiliz...
متن کاملEvaluation of large aberrations using a lateral-shear interferometer having variable shear.
A variable shear lateral shearing interferometer consisting of two holographically produced crossed diffraction gratings is used to test nonrotationally symmetric wavefronts having aberrations greater than 100 wavelengths and slope variations of more than 400 wavelengths/diameter. Comparisons are made with results of Twyman-Green interferometric tests for wavefront aberrations of up to thirty w...
متن کاملQuantitative Data Extraction using Spatial Fourier Transform in Inversion Shear Interferometer
Li, Yanzeng M.S.O.E. Rose-Hulman Institute of Technology May 2014 Quantitative data extraction using spatial Fourier transform in inversion shear interferometer Thesis Advisor: Dr. Scott R. Kirkpatrick Currently there are many interferometers used for testing wavefront, measuring the quality of optical elements, and detecting refractive index changes in a certain medium. Each interferometer has...
متن کاملAnalysis of Frequency Leakage in Different Optical Paths of Nano-Metrology Systems Based on Frequency-Path Models
The drawing of frequency-path (F-P) models of optical beams is an approach for nonlinearity analysis in nano-metrology systems and sensors based on the laser interferometers. In this paper, the frequency-path models of four nano-metrology laser interferometry systems are designed, analyzed and simulated, including ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 14 11 شماره
صفحات -
تاریخ انتشار 1975