Photophysical evaluation of a new functional terbium complex in FRET-based time-resolved homogenous fluoroassays.

نویسندگان

  • Piotr J Cywiński
  • Katia Nchimi Nono
  • Loïc J Charbonnière
  • Tommy Hammann
  • Hans-Gerd Löhmannsröben
چکیده

A new functional luminescent lanthanide complex (LLC) has been synthesized with terbium as a central lanthanide ion and biotin as a functional moiety. Unlike in typical lanthanide complexes assembled via carboxylic moieties, in the presented complex, four phosphate groups are chelating the central lanthanide ion. This special chemical assembly enhances the complex stability in phosphate buffers conventionally used in biochemistry. The complex synthesis strategy and photophysical properties are described as well as the performance in time-resolved Förster Resonance Energy Transfer (FRET) assays. In those assays, this biotin-LLC transferred energy either to acceptor organic dyes (Cy5 or AF680) labelled on streptavidin or to quantum dots (QD655 or QD705) surface-functionalised with streptavidins. The permanent spatial donor-acceptor proximity is assured through strong and stable biotin-streptavidin binding. The energy transfer is evidenced from the quenching observed in donor emission and from a decrease in donor luminescence decay, both associated with simultaneous increase in acceptor intensity and in the decay time. The dye-based assays are realised in TRIS and in PBS, whereas QD-based systems are studied in borate buffer. The delayed emission analysis allows for quantifying the recognition process and for auto-fluorescence-free detection, which is particularly relevant for application in bioanalysis. In accordance with Förster theory, Förster-radii (R0) were found to be around 60 Å for organic dyes and around 105 Å for QDs. The FRET efficiency (η) reached 80% and 25% for dye and QD acceptors, respectively. Physical donor-acceptor distances (r) have been determined in the range 45-60 Å for organic dye acceptors, while for acceptor QDs between 120 Å and 145 Å. This newly synthesised biotin-LLC extends the class of highly sensitive analytical tools to be applied in the bioanalytical methods such as time-resolved fluoroimmunoassays (TR-FIA), luminescent imaging and biosensing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HTRF: A Technology Tailored for Drug Discovery –A Review of Theoretical Aspects and Recent Applications

HTRF (Homogeneous Time Resolved Fluorescence) is the most frequently used generic assay technology to measure analytes in a homogenous format, which is the ideal platform used for drug target studies in high-throughput screening (HTS). This technology combines fluorescence resonance energy transfer technology (FRET) with time-resolved measurement (TR). In TR-FRET assays, a signal is generated t...

متن کامل

Time-Resolved FRET -Based Approach for Antibody Detection – A New Serodiagnostic Concept

Förster resonance energy transfer (FRET) is a phenomenon widely utilized in biomedical research of macromolecular interactions. In FRET energy is transferred between two fluorophores, the donor and the acceptor. Herein we describe a novel approach utilizing time-resolved FRET (TR-FRET) for the detection of antibodies not only in a solution-phase homogenous assay but also in single- and two-step...

متن کامل

A Protein L -Based Immunodiagnostic Approach Utilizing Time-Resolved Förster Resonance Energy Transfer

Chelated lanthanides such as europium (Eu) have uniquely long fluorescence emission half-lives permitting their use in time-resolved fluorescence (TRF) assays. In Förster resonance energy transfer (FRET) a donor fluorophore transfers its emission energy to an acceptor fluorophore if in sufficiently close proximity. The use of time-resolved (TR) FRET minimizes the autofluorescence of molecules p...

متن کامل

Time-resolved luminescence resonance energy transfer imaging of protein-protein interactions in living cells.

Förster resonance energy transfer (FRET) with fluorescent proteins permits high spatial resolution imaging of protein-protein interactions in living cells. However, substantial non-FRET fluorescence background can obscure small FRET signals, making many potential interactions unobservable by conventional FRET techniques. Here we demonstrate time-resolved microscopy of luminescence resonance ene...

متن کامل

Time-Resolved Analysis of a Highly Sensitive Förster Resonance Energy Transfer Immunoassay Using Terbium Complexes as Donors and Quantum Dots as Acceptors

CdSe/ZnS core/shell quantum dots (QDs) are used as efficient Förster Resonance Energy Transfer (FRET) acceptors in a time-resolved immunoassays with Tb complexes as donors providing a long-lived luminescence decay. A detailed decay time analysis of the FRET process is presented. QD FRET sensitization is evidenced by a more than 1000-fold increase of the QD luminescence decay time reaching ca. 0...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical chemistry chemical physics : PCCP

دوره 16 13  شماره 

صفحات  -

تاریخ انتشار 2014