PURPOSE To assess the results and long-term prognosis of evisceration with primary porous implant placement in patients with endophthalmitis. METHODS A retrospective study was conducted to review the files of 27 patients (29 eyes) with endophthalmitis who underwent evisceration with primary porous implant placement from January 1997 to December 2007 at St. Mary's Hospital and Kangnam St. Mary's Hospital. The mean follow-up period was 12.24 months (range, 3 to 89 months) and the mean age of the patients was 63.6 years (range, 33 to 89 years). RESULTS During the surgical procedure, primary implant placement was successfully completed, and any postoperative infection or inflammation rapidly resolved in all 27 patients (29 eyes). One of two porous implant materials was used. Hydroxyapatite was inserted in 14 eyes and Medpor was inserted in 15 eyes. Delayed implant exposure was noted in 1 eye, which was treated by inserting a hydroxyapatite implant 18 months after the first surgery. This was well treated by a preserved scleral graft. Implant infection was noted in 1 other eye at 20 days after the first surgery. All other minor complications healed without sequelae. CONCLUSIONS Evisceration with primary porous implant placement as the treatment for recalcitrant endophthalmitis resulted in rapid resolution of any infection and inflammation. Implant exposure and infection occurred in only 2 eyes, and these problems were well treated without long-term sequelae. Therefore, evisceration with primary porous implant placement is a treatment option for patients with endophthalmitis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of implant extrusion rates and postoperative pain after evisceration with immediate or delayed implants and after enucleation with implants.

PURPOSE To examine implant extrusion rates after evisceration with immediate or delayed implants in patients with culture-proven endophthalmitis. To compare postevisceration and postenucleation pain. METHODS This prospective, nonrandomized interventional case series included four groups of patients: group 1, 25 endophthalmitis patients undergoing evisceration with immediate implants; group 2,...

متن کامل

Autogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere orbital implant exposure.

BACKGROUND Temporalis fascia has been recommended for hydroxyapatite sphere exposure. The aim of this study was to identify potential risk factors for exposure of porous polyethylene (Medpor) sphere implants and evaluate the use of autogenous temporalis fascia as a patch graft for exposure. METHODS A retrospective review of consecutive cases of porous polyethylene sphere orbital implant expos...

متن کامل

Multipurpose conical orbital implant in evisceration.

PURPOSE To evaluate the safety and efficacy of the porous polyethylene multipurpose conical orbital implant for use in evisceration. METHODS A retrospective review of 31 eyes that underwent evisceration and received the multipurpose conical orbital implant. The orbits were evaluated at 1 week, 1 month, and 6 months after final prosthetic fitting for implant exposure, superior sulcus deformity...

متن کامل

Enucleation and evisceration: indications, complications and clinicopathological correlations.

AIM To assess main indications, postoperative complications and clinicopathological correlation of ocular enucleation-evisceration. METHODS A total of 107 subjects who underwent enucleation and/or evisceration and received hydroxyapatite implants (Scleral wrap or mesh) were assessed. For each patient clinicopathological data was collected which included demographic information, clinical histo...

متن کامل

Standard Enucleation with Aluminium Oxide Implant (Bioceramic) Covered with Patient's Sclera

PURPOSE We describe in our study a modified standard enucleation, using sclera harvested from the enucleated eye to cover the prosthesis in order to insert a large porous implant and to reduce postoperative complication rates in a phthisis globe. METHODS We perform initially a standard enucleation. The porous implant (Bioceramic) is then covered only partially by the patient's sclera. The imp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2010