Novel simple templates for reproducible positioning of skin applicators in brachytherapy

نویسندگان

  • Silvia Rodríguez Villalba
  • Maria Jose Perez-Calatayud
  • Juan Antonio Bautista
  • Vicente Carmona
  • Francisco Celada
  • Alejandro Tormo
  • Teresa García-Martinez
  • José Richart
  • Manuel Santos Ortega
  • Magda Silla
  • Facundo Ballester
  • Jose Perez-Calatayud
چکیده

PURPOSE Esteya and Valencia surface applicators are designed to treat skin tumors using brachytherapy. In clinical practice, in order to avoid errors that may affect the treatment outcome, there are two issues that need to be carefully addressed. First, the selected applicator for the treatment should provide adequate margin for the target, and second, the applicator has to be precisely positioned before each treatment fraction. In this work, we describe the development and use of a new acrylic templates named Template La Fe-ITIC. They have been designed specifically to help the clinical user in the selection of the correct applicator, and to assist the medical staff in reproducing the positioning of the applicator. These templates are freely available upon request. MATERIAL AND METHODS Templates that were developed by University and Polytechnic Hospital La Fe (La Fe) and Hospital Clínica Benidorm (ITIC) in cooperation with Elekta, consist of a thin sheet made of transparent acrylic. For each applicator, a crosshair and two different circles are drawn on these templates: the inner one corresponds to the useful beam, while the outer one represents the external perimeter of the applicator. The outer circle contains slits that facilitate to draw a circle on the skin of the patient for exact positioning of the applicator. In addition, there are two perpendicular rulers to define the adequate margin. For each applicator size, a specific template was developed. RESULTS The templates have been used successfully in our institutions for more than 50 patients' brachytherapy treatments. They are currently being used for Esteya and Valencia applicators. CONCLUSIONS The template La Fe-ITIC is simple and practical. It improves both the set-up time and reproducibility. It helps to establish the adequate margins, an essential point in the clinical outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo investigation on precise dosimetry of HDR breast brachytherapy with Accuboost

Introduction: Accuboost is a HDR brachytherapy system in early stages breast cancer treatment. This device provides a completely noninvasive procedure with parallel-opposed radiation from two immobilizing peripheral applicators that caused it a preferred option of modalities to choose. In most commercial treatment planning systems, tissues are considered as a simple water phan...

متن کامل

Evaluation of BEBIG HDR 60Co system for non-invasive image-guided breast brachytherapy

PURPOSE HDR (60)Co system has recently been developed and utilized for brachytherapy in many countries outside of the U.S. as an alternative to (192)Ir. In addition, the AccuBoost(®) technique has been demonstrated to be a successful non-invasive image-guided breast brachytherapy treatment option. The goal of this project is to evaluate the possibility of utilizing the BEBIG HDR (60)Co system f...

متن کامل

Evaluation of dose distribution and dose gradient in brachytherapy cylindrical applicators using a dedicated Phantom for Iridium-192 and Cobalt-60 HDR sources

Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments.   Materials and Methods: Two additional computed tomography (CT) based plans were generated using a ...

متن کامل

Application of the thermoluminescent technique for calibration and dosimetry of 90 Sr + 90 Y applicators

Dermatological and ophthalmic applicators are used in brachytherapy for the treatment of superficial lesions of skin and eyes. The calibration of these applicators should be realized periodically, according to quality control programs and international recommendations about dosimetry and calibration of brachytherapy sources. Thin thermoluminescent dosimeters of CaSO4:Dy were utilized in this wo...

متن کامل

Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2016