Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma

نویسندگان

  • Sung Yong Kang
  • Samin Hong
  • Jung Bin Won
  • Gong Je Seong
  • Chan Yun Kim
چکیده

PURPOSE To assess the accuracy of intraocular lens (IOL) power predictions for cataract surgery in eyes with primary angle-closure glaucoma (ACG). Because of shifting of the capsular bag apparatus and shortening of the axial length, preoperative calculation of IOL power may be inaccurate for eyes with ACG. MATERIALS AND METHODS This retrospective comparative case series comprised of 42 eyes from 42 patients with primary ACG and 45 eyes from 45 subjects with normal open-angles undergoing uneventful cataract surgery. Anterior segment biometry including anterior chamber depth, lens thickness, and axial length were compared. Using the SRK-II formula, the powers of the implanted IOL and the actual postoperative spherical equivalent (SE) refractive errors were compared between the two groups. Also, the absolute values of differences between predicted and residual SE refractive errors were also analyzed for each group. RESULTS In ACG patients, anterior chamber depth and axial length were shorter and the lens was thicker than normal controls (all p < 0.001). Even though residual SE refractive error was not significantly different (p = 0.290), the absolute value of the difference between predicted and residual SE refractive error was 0.64 +/- 0.50 diopters in AGC patients and 0.39 +/- 0.36 diopters in control subjects (p = 0.012). The number of eyes that resulted in inaccurate IOL power predictions of more than 0.5 diopters were 21 (50.00%) in the ACG group, but only 12 (26.67%) in the control group (p = 0.043). CONCLUSION IOL power predictions for cataract surgery in ACG patients can be inaccurate, and it may be associated with their unique anterior segment anatomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lens-based glaucoma surgery: using cataract surgery to reduce intraocular pressure.

UNLABELLED Cataract surgery has been demonstrated to lower intraocular pressure (IOP) in eyes with glaucoma. The evidence is strong in angle-closure patients that cataract surgery improves IOP and dramatically reduces the future risk for IOP spikes and acute attacks. Randomized controlled trials (RCTs) have shown that cataract surgery may be preferable to laser iridotomy or phacotrabeculectomy....

متن کامل

Accuracy of Intraocular Lens Power Calculation Formulas in Primary Angle Closure Glaucoma

PURPOSE To compare the accuracy of intraocular lens (IOL) power calculation formulas in eyes with primary angle closure glaucoma (ACG). METHODS This retrospective study compared the refractive outcomes of 63 eyes with primary ACG with the results of 93 eyes with normal open angles undergoing uneventful cataract surgery. Anterior segment biometry including anterior chamber depth, axial length,...

متن کامل

Reduction of intraocular pressure and improvement of vision after cataract surgeries in angle closure glaucoma with concomitant cataract patients.

OBJECTIVE This study is to compare the efficacy of three different cataract surgeries in eyes with angle closure glaucoma (ACG) with concomitant cataract. METHODS A retrospective comparative analysis of 106 ACG patients (112 eyes) with concomitant cataract was conducted between February, 2012 and February, 2014. Clinical outcomes of ACG patients with concomitant cataract underwent phacoemulsi...

متن کامل

Effects of phacoemulsification and intraocular lens implantation combined with ciliarotomy in the treatment of angle-closure glaucoma with cataract

The aim of the present study was to examine the effects of phacoemulsification and intraocular lens implantation combined with ciliarotomy in the treatment of angle-closure glaucoma with cataract in the elderly. A total of 68 patients were consecutively selected and divided into the control group with 33 cases (48 eyes) and the observation group with 35 cases (53 eyes). Cataract surgery combine...

متن کامل

The role of clear lens extraction in angle closure glaucoma

Clear lens extraction can be considered a therapeutic option in angle closure glaucoma (ACG). Even if it does not represent the first choice of treatment, it can be taken into consideration when the topical treatment does not control the intraocular pressure (IOP) and iridotomy does not have a positive effect on the angle closure, especially in appositional angle closure when biometry or ultrab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 50  شماره 

صفحات  -

تاریخ انتشار 2009