Prevention of hot spot temperature in a distribution transformer using magnetic fluid as a coolant
نویسندگان
چکیده
A MneZn ferrite magnetic fluid (TCF-56) having 5.6 mT fluid magnetization and high pyromagnetic coefficient, (vM/vT 1⁄4 177 A/m K) has been investigated as a coolant in a 3 kW prototype transformer for overloading condition (167%). The winding temperature of a transformer submerged in magnetic fluid reaches at 396.8 K after 3 h of overloading, which is 20 K lower, when the same experiment was carried out with pure transformer oil. Similarly, core and top oil temperature also decrease by 14 and 21 K, respectively, when TCF-56 is used. This cooling performance of TCF-56 attributes to the thermo-magnetic convection, which sets up due to the significant change in magnetization of the fluid with increasing temperature. This can be explained using the Rayleigh number. The normal life of a transformer under 167% overloading condition is calculated for pure oil and TCF-56. The result shows nine times increase in normal life expectancy in TCF-56 fluid compared to use of pure oil. The study leads to the conclusion that MneZn ferrite magnetic fluid (TCF-56) used in a transformer can deliver more power than its nameplate rating with an improved normal life. © 2015 Elsevier Masson SAS. All rights reserved.
منابع مشابه
Different Electric Vehicle Charging Strategies to avoid Reducing the Insulation Oil Lifetime of Distribution Transformers
Abstract: The widespread presence of uncontrolled electric vehicles causes overloading of distribution network equipment. One of these equipments is distribution transformer, which should pay attention to overloading and reducing lifetime of this equipment due to charging of electric vehicles. First, strategies have been proposed to investigate the effect of electric vehicle penetration level a...
متن کاملSimulation of Subcooled Flow Boiling Occurring in Internal Combustion Engine Water Jacket by Numerical Modeling in a Channel with Hot Spot
Boiling heat transfer always has been proposed as a solution for enhancing heat transfer between the fluid and solid surfaces. Subcooled flow boiling is one of the mechanisms that occur in Internal Combustion Engine water jacket in which high amounts of heat is transferred. In this research, it has been tried to simulate subcooled flow boiling in a geometry similar to coolant channel inside the...
متن کاملHot Spot Temperature Analysis in 3 Phase Transformers Using FEM Method
Transformers represent the largest portion of capital investment in transmission and distribution substations. In addition, transformer outages have a considerable economic impact on the operation of an electrical network. Hot-spot temperature (HST) value is a significant factor that directly impacts on the operation of transformers. For this purpose, energy (thermal) and Maxwell equation are s...
متن کاملمدلسازی اثر بارگذاری بر قابلیت اطمینان ترانسفورمر
Transformer is one of the most important components of power system, which determining its reliability is very important. To evaluate transformer overall reliability, in addition to probability of failures occur due to chance events, the probability of failures owing to aging should be taken into account. To determine transformer reliability in aging area, estimating its remaining life is of gr...
متن کاملHottest Spot and Life Evaluation of Power Transformer Design Using Finite Element Method
Power transformers represent the largest portion of capital investment in transmission and distribution substations. In addition, power transformer outages have a considerable economic impact on the operation of an electrical network. One of the most important parameters’ governing a transformer’s life expectancy is the hot-spot temperature value. Due to under estimation of stray losses in powe...
متن کامل