The Value of 320-Row Multidetector CT Bronchial Arteriography in Recurrent Hemoptysis after Failed Transcatheter Arterial Embolization.

نویسندگان

  • Tian Zhao
  • Sini Wang
  • Lili Zheng
  • Zhongzhi Jia
  • Yunjun Yang
  • Weiping Wang
  • Houzhang Sun
چکیده

PURPOSE To retrospectively assess the value of computed tomographic (CT) bronchial arteriography (BA) with 320-row multidetector CT in the management of patients with recurrent hemoptysis immediately after bronchial artery embolization (BAE). MATERIALS AND METHODS Among 135 consecutive patients treated with BAE between April 2014 and March 2016, recurrent hemoptysis developed in 15, and 10 subsequently underwent multidetector CT. Vascular abnormalities and associated anatomy were evaluated to determine the potential cause of BAE failure, and the clinical impacts of CT BA were analyzed. RESULTS CT BA revealed an additional 22 abnormal vessels in the qualified 10 patients, and 8 patients were treated again within 24 hours after the first BAE based on multidetector CT findings. Of the 22 abnormal vessels, 16 were embolized, including 4 orthotopic arteries, 8 ectopic arteries, and 4 nonbronchial systemic arteries (NBSAs); the remaining 6 abnormal arteries were not embolized because of normal BA (n = 1), anatomic inaccessibility (n = 2), or cessation of hemoptysis with conservative therapy (n = 3). There were no further cases of recurrent hemoptysis after the second intervention, with a mean follow-up of 7.7 months ± 6.7. Overall, initial conventional BA missed 65% of potential bleeding arteries (22 of 34). After CT BA, 73% of the newly identified vessels (16 of 22) were embolized. CONCLUSIONS Multiple unrecognized abnormal ectopic bronchial arteries and NBSAs are the major causes of failure of initial BAE. Multidetector CT BA can precisely identify a large number of feeding vessels that are missed on conventional BA, allowing for repeat embolization with a high success rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volume-rendered hemorrhage-responsible arteriogram created by 64 multidetector-row CT during aortography: utility for catheterization in transcatheter arterial embolization for acute arterial bleeding

Aortography for detecting hemorrhage is limited when determining the catheter treatment strategy because the artery responsible for hemorrhage commonly overlaps organs and non-responsible arteries. Selective catheterization of untargeted arteries would result in repeated arteriography, large volumes of contrast medium, and extended time. A volume-rendered hemorrhage-responsible arteriogram crea...

متن کامل

Multidetector CT of bronchial and non-bronchial systemic arteries.

We evaluate the use of multidetector row computed tomography (MDCT) angiography for the depiction of bronchial and non-bronchial systemic arteries (NBSAs), which frequently become enlarged as a secondary finding in a wide array of chronic lung diseases and other diseases that affect the pulmonary vascular system. MDCT angiography has enabled radiologists to provide thin-slice axial images, mult...

متن کامل

The Factors Related to Recurrence after Transcatheter Arterial Embolization for the Treatment of Hemoptysis

OBJECTIVES Massive hemoptysis is a major clinical problem associated with high morbidity and mortality. Transcatheter arterial embolization is widely used for the treatment of massive hemoptysis, but it was reported that the recurrence rate after embolization is 12-54% in the previous studies. We evaluated the therapeutic effect of transcatheter arterial embolization for the treatment of massiv...

متن کامل

Use of multidetector row CT to evaluate the need for bronchial arterial embolization in hemoptysis patients.

BACKGROUND Bronchial artery (BA) embolization (BAE) is recommended as a minimally invasive therapy for hemoptysis, though some patients recover after only conservative treatment. OBJECTIVES The purpose of our study was to assess the characteristics of BAs using multidetector row computed tomography (MDCT) and identify BAs requiring BAE without BA angiography (BAG). METHODS We retrospectivel...

متن کامل

Bronchial Artery Embolization for Hemoptysis: A Retrospective Observational Study of 344 Patients

BACKGROUND Hemoptysis is a significant clinical entity with high morbidity and potential mortality. Both medical management (in terms of resuscitation and bronchoscopic interventions) and surgery have severe limitations in these patients population. Bronchial artery embolization (BAE) represents the first-line treatment for hemoptysis. This article discusses clinical analysis, embolization appr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular and interventional radiology : JVIR

دوره 28 4  شماره 

صفحات  -

تاریخ انتشار 2017