Analyzing human decisions in IGRT of head-and-neck cancer patients to teach image registration algorithms what experts know

نویسندگان

  • Eva Maria Stoiber
  • Nina Bougatf
  • Hendrik Teske
  • Christian Bierstedt
  • Dieter Oetzel
  • Jürgen Debus
  • Rolf Bendl
  • Kristina Giske
چکیده

BACKGROUND In IGRT of deformable head-and-neck anatomy, patient setup corrections are derived by rigid registration methods. In practice, experienced radiation therapists often correct the resulting vectors, thus indicating a different prioritization of alignment of local structures. Purpose of this study is to transfer the knowledge experts apply when correcting the automatically generated result (pre-match) to automated registration. METHODS Datasets of 25 head-and-neck-cancer patients with daily CBCTs and corresponding approved setup correction vectors were analyzed. Local similarity measures were evaluated to identify the criteria for human corrections with regard to alignment quality, analogous to the radiomics approach. Clustering of similarity improvement patterns is applied to reveal priorities in the alignment quality. RESULTS The radiation therapists prioritized to align the spinal cord closest to the high-dose area. Both target volumes followed with second and third highest priority. The bony pre-match influenced the human correction along the crania-caudal axis. Based on the extracted priorities, a new rigid registration procedure is constructed which is capable of reproducing the corrections of experts. CONCLUSIONS The proposed approach extracts knowledge of experts performing IGRT corrections to enable new rigid registration methods that are capable of mimicking human decisions. In the future, the deduction of knowledge-based corrections for different cohorts can be established automating such supervised learning approaches.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of image-guided radiotherapy for laryngeal sparing in head and neck cancer.

We would like to compare the effectiveness of image-guided (IGRT) and intensity-modulated (IMRT) radiotherapy to spare the larynx in head and neck cancer patients. A retrospective review of 48 patients undergoing radiation for non-laryngeal and non-hypopharyngeal head and neck cancers. Mean laryngeal and hypopharyngeal dose was compared between 11 patients treated with IMRT and 37 patients trea...

متن کامل

IGRT versus non-IGRT for postoperative head-and-neck IMRT patients: dosimetric consequences arising from a PTV margin reduction

BACKGROUND To evaluate the impact of image-guided radiation therapy (IGRT) versus non-image-guided radiation therapy (non-IGRT) on the dose to the clinical target volume (CTV) and the cervical spinal cord during fractionated intensity-modulated radiation therapy (IMRT) for head-and-neck cancer (HNC) patients. MATERIAL AND METHODS For detailed investigation, 4 exemplary patients with daily con...

متن کامل

Feasibility of Tomotherapy-Based Image-Guided Radiotherapy to Reduce Aspiration Risk in Patients with Non-Laryngeal and Non-Pharyngeal Head and Neck Cancer

PURPOSE The study aims to assess the feasibility of Tomotherapy-based image-guided radiotherapy (IGRT) to reduce the aspiration risk in patients with non-laryngeal and non-hypopharyngeal cancer. A retrospective review of 48 patients undergoing radiation for non-laryngeal and non-hypopharyngeal head and neck cancers was conducted. All patients had a modified barium swallow (MBS) prior to treatme...

متن کامل

The Reproducibility of Patient Setup for Head and Neck Cancers Treated with Image-Guided and Intensity-Modulated Radiation Therapies Using Thermoplastic Immobilization Device

The reproducibility of patient setup is an important issue for head and neck cancers treated with intensity-modulated radiation therapy (IMRT). In this study, an image-guided radiation therapy (IGRT) system has been used to minimize the uncertainty of patient setup while standard thermoplastic masks were used to provide adequate immobilization for the head and neck. However, they do not provide...

متن کامل

Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy

Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...