Improving CBF Image Contrast with Frequency Extrapolation for DSC-MRI during Acute Stroke
نویسندگان
چکیده
Introduction: Dynamic susceptibility contrast (DSC) MR imaging can be used to determine the perfusion state of brain tissue during acute ischemic stroke. Perfusion-weighted imaging (PWI) when combined with diffusion-weighted imaging (DWI) has been proposed as a method for determining the volume of salvageable tissue during initial hours of onset (< 6 h) [1]. Use of the cerebral blood flow (CBF) estimates obtained from PWI is effective at identifying ischemic tissue, however, the accuracy of this parameter has been observed to vary in performance with the type of deconvolution technique used for its calculation [2]. Several deconvolution methods have been observed to have an MTT dependence due to regularization, resulting in an underestimation of CBF values in healthy tissues (i.e., healthy tissues have shorter mean-transit times (MTT) and are more heavily filtered, while ischemic tissue has longer MTT and less signal removed) [3]. We hypothesize that by restoring high-frequency components during the deconvolution process, there will be an improvement observed in the CBF accuracy and in image contrast between healthy and ischemic regions, resulting in better detection of final infarct. Methods A 3 T MR scanner (Signa VH/i, General Electric Healthcare, Waukesha, WI) was used for imaging of acute stroke. As part of the standard stroke imaging protocol, patients receive whole-brain PWI (TR/TE/flip = 2000 ms/30 ms/45) and DWI. From our studies, ten ischemic stroke patient data sets were assessed. Five deconvolution methods were compared with respect to CBF maps: 1) spectral division, 2) block-circulate singular value decomposition, 3) Tikhonov based singular value decomposition, 4) Tikhonov regularization, and 5) frequency-domain extrapolated spectral division. The extrapolated method restores the attenuated highfrequency components by linearly estimating the filtered coefficients during deconvolution. Each method was optimized by finding the parameter values that minimized the CBF error via simulations. Image contrast between healthy and ischemic tissue, in both grey matter (GM) and white matter (WM), were measured. A two-way (factors: tissue type and deconvolution method) repeated-measures ANOVA test was used to determine the significance of differences (p < 0.05). Receiver operator characteristic (ROC) analysis was performed on one untreated patient who had follow-up imaging 30 days later, allowing for MR assessment of the final infarct. Results Across the ten patient data sets there was a mean increase in healthyischemic tissue CBF image contrast with the simple extrapolation method when compared to the other methods (average image contrast increased between 125 % and 266 %, depending on method and tissue type, p = 0.001. The simple extrapolation method generated CBF maps with significant increase of image contrast for WM when compared with methods 1) ,2) and 4) (labeled above) and GM for methods 1) and 2). While each technique permitted the penumbra to be determined on visual inspection (Fig 1), ROC analysis clearly showed the proposed extrapolation approached outperformed the other techniques. Conclusions The simple extrapolation method resulted in improved contrast between healthy and ischemic tissue. By restoring the high frequency components during the deconvolution process, better tissue state prediction was achieved, improving the estimates of DSC. References: 1. Easton et al., Stroke, 2009; 40:2276-2293 2. Salluzzi, et al., Magn Reson Image 2005; 3:481. 3. Carpenter, et al., Magn Reson Med 2006; 55:1342. Fig 1: Initial DWI image and 30 day follow up FLAIR scans. Several CBF maps are processed from deconvolution techniques. These maps are compared with ROC analysis based on 30 day infarct.
منابع مشابه
Abnormal intravoxel cerebral blood flow heterogeneity in human ischemic stroke determined by dynamic susceptibility contrast magnetic resonance imaging.
BACKGROUND AND PURPOSE The determination of cerebral blood flow heterogeneity (FH) by dynamic susceptibility contrast (DSC) magnetic resonance imaging has recently been proposed as a tool to predict final infarct size in acute stroke. In this study, we describe the evolution of FH during the first week as well as its correlation to the patients' clinical status. METHODS Ten patients with isch...
متن کاملComparison of Arterial Spin Labeling and Dynamic Susceptibility Contrast Perfusion MRI in Patients with Acute Stroke
BACKGROUND The aim of this study was to evaluate whether arterial spin labeling (ASL) perfusion magnetic resonance imaging (MRI) can reliably quantify perfusion deficit as compared to dynamic susceptibility contrast (DSC) perfusion MRI. METHODS Thirty-nine patients with acute ischemic stroke in the anterior circulation territory were recruited. All underwent ASL and DSC MRI perfusion scans wi...
متن کاملArterial spin labeling and dynamic susceptibility contrast CBF MRI in postischemic hyperperfusion, hypercapnia, and after mannitol injection.
Arterial spin labeling (ASL) and dynamic susceptibility contrast (DSC) magnetic resonance imaging (MRI) are widely used to image cerebral blood flow (CBF) in stroke. This study examined how changes in tissue spin-lattice relaxation-time constant (T(1)), blood-brain barrier (BBB) permeability, and transit time affect CBF quantification by ASL and DSC in postischemic hyperperfusion in the same an...
متن کاملMulti-delay multi-parametric arterial spin-labeled perfusion MRI in acute ischemic stroke — Comparison with dynamic susceptibility contrast enhanced perfusion imaging☆
The purpose of the present study was to present a multi-delay multi-parametric pseudo-continuous arterial spin labeling (pCASL) protocol with background suppressed 3D GRASE (gradient and spin echo) readout for perfusion imaging in acute ischemic stroke. PCASL data at 4 post-labeling delay times (PLD = 1.5, 2, 2.5, 3 s) were acquired within 4.5 min in 24 patients (mean age 79.7 ± 11.4 years; 11 ...
متن کاملAn anisotropic diffusion method for denoising dynamic susceptibility contrast-enhanced magnetic resonance images.
The purpose of this study was to present an application of a novel denoising technique for improving the accuracy of cerebral blood flow (CBF) images generated from dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI). The method presented in this study was based on anisotropic diffusion (AD). The usefulness of this method was firstly investigated using computer simulat...
متن کامل