Modified robotic-assisted thyroidectomy: an initial experience with the retroauricular approach.

نویسندگان

  • Emad Kandil
  • Ahmad Saeed
  • Salah E Mohamed
  • Nuha Alsaleh
  • Rizwan Aslam
  • Thomas Moulthrop
چکیده

OBJECTIVES/HYPOTHESIS New approaches for robotic-assisted thyroidectomy, including the retroauricular approach, were recently described. We have modified the established surgical approach for retroauricular robotic thyroidectomy. Herein, we report our initial experience to identify challenges and limitations of this new surgical approach. STUDY DESIGN Prospective case series. METHODS This study was performed under institutional review board approval for patients who underwent retroauricular robotic hemithyroidectomy at an academic North American institution. The retroauricular approach was modified by using the space between the two heads of the sternocleidomastoid muscle as our working space. Additionally, selected patients underwent concomitant neck lift surgery with robotic thyroid surgery. Clinical characteristics, total operative time, blood loss, surgical outcomes, and length of hospital stay were evaluated. RESULTS Twelve female patients were included in this study. Mean age was 45 ± 4.43 years, and mean body mass index was 28.6 ± 2.15. Mean thyroid nodule size was 1.15 ± 0.26 cm(3). All cases were completed successfully via single retroauricular incision. There was no conversion to an open approach. Four out of 12 patients (33%) underwent additional concomitant neck lift surgery, with a mean total operative time of 156 ± 15.88 minutes. The mean operative time for the remaining eight patients who underwent the robotic approach without additional neck lift surgery was 145.4 ± 10.08 minutes. There were no cases of permanent vocal cord paralysis or permanent hypoparathyroidism. Mean blood loss was 22.4 ± 4.32 mL. Four patients (33%) were discharged home on the same day of surgery, and the remaining eight patients were discharged after an overnight stay. CONCLUSIONS Single-incision retroauricular robotic hemithyroidectomy can be a safe and feasible alternative to other remote access techniques. Neck lift surgery can be performed safely in a select group of patients. However, future studies are warranted to further evaluate the benefits and limitations of this novel approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retroauricular Endoscope-Assisted Approach to the Neck: Early Experience in Latin America.

Introduction There has been a significant increase in concern towards improving aesthetic and functional outcomes without compromising the oncologic effectiveness in head and neck surgery. In this subset, endoscope-assisted and robotic procedures allowed the development of new approaches to the neck, including the retroauricular access, which is now routinely used, especially in Korea. Objectiv...

متن کامل

Minimal Endoscope-assisted Thyroidectomy Through a Retroauricular Approach: An Evolving Solo Surgery Technique

This study aimed to evaluate the feasibility and efficacy of minimal endoscope-assisted thyroidectomy (MEAT) through a retroauricular (RA) approach. Most of the thyroidectomy operative time was accounted for by direct visualization through the RA window, minimizing interference between surgical instruments. Endoscope use was minimized and limited to critical surgical aspects, including preserva...

متن کامل

Initial experience with robot-assisted modified radical neck dissection for the management of thyroid carcinoma with lateral neck node metastasis.

BACKGROUND Since the introduction of endoscopic techniques in thyroid surgery, several trials of endoscopic lateral neck dissection have been conducted with the aim of avoiding a long cervical scar, but these endoscopic procedures require more effort than open surgery, mainly because of the relatively nonsophisticated instruments used. However, the recent introduction of surgical robotic system...

متن کامل

Robotic thyroid surgery: our experience with the infraclavicular approach.

BACKGROUND Robot-assisted endoscopic transaxillary thyroidectomy is an emerging surgical technique. Despite promising results it presents some limitations and remains controversial in terms of usefulness and validity. We developed an alternative robotic technique using a gasless infraclavicular approach. METHODS We tested this approach using cadaveric dissection, then we performed the techniq...

متن کامل

Esthetic neck dissection using an endoscope via retroauricular incision: a report of two cases

Various surgical techniques, such as endoscopic surgery and robotic surgery, are developed to optimize the esthetic outcome even in operations for malignancy. A modified face-lift or retroauricular approach are used to minimize postoperative scarring. Recently, robot-assisted surgery is being done in various fields and considered as favorable treatment method by many surgeons. However its high ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Laryngoscope

دوره 125 3  شماره 

صفحات  -

تاریخ انتشار 2015