In vivo quantitation of peroxides in the vitreous humor by fluorophotometry.

نویسندگان

  • H Taguchi
  • Y Ogura
  • T Takanashi
  • M Hashizoe
  • Y Honda
چکیده

PURPOSE To detect intravitreal peroxides in vivo by a new fluorophotometric method with a hydrogen peroxide (H2O2)-sensitive fluorescent dye. METHODS The authors used a 2',7'-dichlorofluorescin (DCFH) assay to measure oxidative status in the rabbit vitreous. In the presence of H2O2 and lipid hydroperoxides, nonfluorescent DCFH in the vitreous is oxidized to highly fluorescent 2',7'-dichlorofluorescein (DCF; excitation, 495 nm; emission, 520 nm) that is detectable by fluorophotometry. Reactions of DCFH with various concentrations of H2O2 were investigated in vitro and in vivo. An inhibitory effect of catalase also was monitored. Vitreous fluorophotometry with DCFH was performed immediately and at 3, 7, and 28 days after constant light exposure to the retina (1800 lux, 24 hours) as an oxidative stress. RESULTS In vitro study revealed that H2O2 oxidized DCFH to DCF in a dose-dependent manner, ranging from 0.1 to 100 mmol/1 in concentration. Catalase inhibited DCF production. Vitreous fluorophotometry demonstrated that H2O2 oxidized DCFH to DCF in vivo in a dose-dependent manner, ranging from 0.06 to 60 mmol/1 in concentration. DCF production in the vitreous significantly increased immediately (P = 0.03) and at 3 days (P = 0.01) and 7 days (P = 0.01) after light exposure, and it returned to the pretreatment level by day 28. CONCLUSIONS The results suggest that this fluorophotometric method quantitatively can detect intravitreal peroxides in vivo. This method will be helpful to study the oxidative status in some experimental pathologic conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorophotometric detection of intravitreal peroxides after panretinal laser photocoagulation.

PURPOSE To develop a highly sensitive method for in vivo quantitation of intravitreal peroxides by vitreous fluorophotometry with 2',7'-dichlorofluorescin (DCFH), a hydrogen peroxide (H2O2)-sensitive fluorescent dye, and to measure peroxides in the vitreous humor after panretinal laser photocoagulation (PRP). METHODS In the presence of H2O2 and lipid hydroperoxides, nonfluorescent DCFH was ox...

متن کامل

A new vitreal drug delivery system using an implantable biodegradable polymeric device.

PURPOSE The authors evaluated the feasibility of using an implantable biodegradable polymeric device to deliver drugs into the vitreous humor. METHODS Two types of devices were prepared by compression-molding polymers of poly(DL-lactic acid) of two different molecular weights. The molecular weights of the poly(DL-lactic acid) used were 5,600 (device-1) and 9,100 (device-2). Sodium fluorescein...

متن کامل

Vitreous fluorophotometry: mathematical analysis of the effect of peripheral leakage on axial scans.

Current instrumentation in vitreous fluorophotometry allows the determination of a fluorescein concentration profile along the optical axis of the eye. Based on an assumption of a uniform blood-retinal barrier permeability, several methods have been used for the determination of the permeability from an axial scan. The assumption of a uniform permeability is not realistic and it has been unknow...

متن کامل

Effects of Al3+ and Be2+ ions combined with NaF on ciliary process adenylyl cyclase activity and aqueous humor dynamics in the rabbit eye.

PURPOSE The activity of Al3+, Ga3+, and Be2+ ions in the presence of NaF to directly activate G-proteins was investigated by their potentiative effect on forskolin (FSK)-activated adenylyl cyclase in rabbit ciliary process membranes and their effects on aqueous humor dynamics in vivo. METHODS Adenylyl cyclase (AC) was determined by radiometric conversion of ATP to cAMP by the particulate frac...

متن کامل

Ethanol Concentration and Its Correlation with CNS Suppressor Drugs in Postmortem Subjects

Background: Many studies have been done in order to interpret correctly the results of ethanol analysis and its related problems. Unfortunately, it was not easy to determine BAC rate, due to postmortem different conditions or personal and clinical differences in metabolism and excretion of ethanol. The time between death and autopsy, the environmental conditions (temperature and humidity) are i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 37 7  شماره 

صفحات  -

تاریخ انتشار 1996