Left Ventricular Function Evaluation on a 3T MR Scanner with Parallel RF Transmission Technique: Prospective Comparison of Cine Sequences Acquired before and after Gadolinium Injection

نویسندگان

  • Thibault Caspar
  • Anthony Schultz
  • Mickaël Schaeffer
  • Aïssam Labani
  • Mi-Young Jeung
  • Paul Thomas Jurgens
  • Soraya El Ghannudi
  • Catherine Roy
  • Mickaël Ohana
چکیده

OBJECTIVES To compare cine MR b-TFE sequences acquired before and after gadolinium injection, on a 3T scanner with a parallel RF transmission technique in order to potentially improve scanning time efficiency when evaluating LV function. METHODS 25 consecutive patients scheduled for a cardiac MRI were prospectively included and had their b-TFE cine sequences acquired before and right after gadobutrol injection. Images were assessed qualitatively (overall image quality, LV edge sharpness, artifacts and LV wall motion) and quantitatively with measurement of LVEF, LV mass, and telediastolic volume and contrast-to-noise ratio (CNR) between the myocardium and the cardiac chamber. Statistical analysis was conducted using a Bayesian paradigm. RESULTS No difference was found before or after injection for the LVEF, LV mass and telediastolic volume evaluations. Overall image quality and CNR were significantly lower after injection (estimated coefficient cine after > cine before gadolinium: -1.75 CI = [-3.78;-0.0305], prob(coef>0) = 0% and -0.23 CI = [-0.49;0.04], prob(coef>0) = 4%) respectively), but this decrease did not affect the visual assessment of LV wall motion (cine after > cine before gadolinium: -1.46 CI = [-4.72;1.13], prob(coef>0) = 15%). CONCLUSIONS In 3T cardiac MRI acquired with parallel RF transmission technique, qualitative and quantitative assessment of LV function can reliably be performed with cine sequences acquired after gadolinium injection, despite a significant decrease in the CNR and the overall image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid functional cardiac imaging after gadolinium injection: Evaluation of a highly accelerated sequence with sparse data sampling and iterative reconstruction

To generate a patient-friendly, time-efficient cardiac MRI examination protocol, a highly accelerated real-time CINE MR sequence (SSIR) was acquired in the idle time in between contrast injection and late gadolinium enhancement phase. 20 consecutive patients underwent a cardiac MRI examination including a multi-breath-hold sequence as gold standard (Ref) as well as SSIR sequences with (SSIR-BH)...

متن کامل

Magnetic Resonance Spectroscopy of the Breast at 3T: Pre- and Post-Contrast Evaluation for Breast Lesion Characterization

PURPOSE To determine whether in vivo proton magnetic resonance spectroscopy at 3T can provide accurate breast lesion characterization, and to determine the effect of gadolinium on the resonance of tCho. METHODS Twenty-four positive-mammogram patients were examined on a 3T MR scanner. 1H-MRS was performed before and after gadolinium administration. tCho peak was qualitatively evaluated before ...

متن کامل

Accurate assessment of ventricular volumes in a single breath hold using a 32-channel coil and an extracellular contrast agent

Introduction: Functional assessment of cardiac ventricles is an essential aspect of cardiac MR. It provides regional wall motion abnormalities and volumetric data which are important clinical measures. Traditionally cine images are acquired in the short axis (SA) orientation with multiple slices through the ventricles. Although well validated one draw back of this technique is that the multiple...

متن کامل

Left ventricular function, aortic velocity, and late gadolinium enhancement assessed by real-time and single shot CMR is comparable to breath-held segmented imaging: a prospective study

Methods Thirteen patients referred to the CMR lab for evaluation of undiagnosed cardiomyopathy were prospectively enrolled. All patients were in regular cardiac rhythm and able to breath-hold. Standard segmented k-space images (including cine, velocity mapping (VM), and late-gadolinium enhancement (LGE)) were acquired during breathhold; real-time images (including cine, VM, and LGE) were acquir...

متن کامل

Single breath-hold real-time MR cardiac cine for evaluation of left ventricular function

Background Magnetic Resonance (MR) cardiac cine is generally accepted as the gold standard for left ventricular (LV) volume assessment. Recently, Real-Time (RT) cine with sparse sampling technique and iterative reconstruction has been applied to accelerate cine MR. However, in prospective electrocardiogram (ECG) triggered RT cine MR, it may be difficult to capture the true end diastole phase be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016