Evaluation of Deformable Image Registration

نویسنده

  • Joshua Bird
چکیده

Deformable image registration (DIR) is a type of registration that calculates a deformable vector field (DVF) between two image data sets and permits contour and dose propagation. However the calculation of a DVF is considered an ill-posed problem, as there is no exact solution to a deformation problem, therefore all DVFs calculated contain errors. As a result it is important to evaluate and assess the accuracy and limitations of any DIR algorithm intended for clinical use. The influence of image quality on the DIR algorithms performance was also evaluated. The hybrid DIR algorithm in RayStation 4.0.1.4 was assessed using a number of evaluation methods and data. The evaluation methods were point of interest (POI) propagation, contour propagation and dose measurements. The data types used were phantom and patient data. A number of metrics were used for quantitative analysis and visual inspection was used for qualitative analysis. The quantitative and qualitative results indicated that all DVFs calculated by the DIR algorithm contained errors which translated into errors in the propagated contours and propagated dose. The results showed that the errors were largest for small contour volumes (<20cm3) and for large anatomical volume changes between the image sets, which pushes the algorithms ability to deform, a significant decrease in accuracy was observed for anatomical volume changes of greater than 10%. When the propagated contours in the head and

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of deformable image registration in HDR gynecological brachytherapy

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...

متن کامل

A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images

Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...

متن کامل

Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy

Deformable image registration is a powerful tool for mapping information, such as radiation therapy dose calculations, from one computed tomography image to another. However, deformable image registration is susceptible to mapping errors. Recently, an automated deformable image registration evaluation of confidence tool was proposed to predict voxel-specific deformable image registration dose m...

متن کامل

A Novel Framework for Deformable Registration Evaluation and Quality Assurance

Purpose Deformable registration is now routinely used at many radiation oncology centers not only for automatic contouring, but also for diagnostic image registration and dose accumulation. In these applications, it is essential that these registrations are not only characterized with phantom studies, but also be checked on a per-patient basis around the regions where the deformable registratio...

متن کامل

Quantitative evaluation of a cone‐beam computed tomography–planning computed tomography deformable image registration method for adaptive radiation therapy

Deformable (non-rigid) registration is an essential tool in both adaptive radiation therapy and image-guided radiation therapy to account for soft-tissue changes during the course of treatment. The evaluation method most commonly used to assess the accuracy of deformable image registration is qualitative human evaluation. Here,we propose a method for systematically measuring the accuracy of an ...

متن کامل

Assessment of a commercially available automatic deformable registration system

In recent years, a number of approaches have been applied to the problem of deformable registration validation. However, the challenge of assessing a commercial deformable registration system - in particular, an automatic registration system in which the deformable transformation is not readily accessible - has not been addressed. Using a collection of novel and established methods, we have dev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015