Laboratory experience with radiometric detection of bacteremia with three culture media.
نویسندگان
چکیده
In two long-term studies, the BACTEC radiometric system for detection of bacteremia was evaluated with three culture media each: (i) BACTEC media 6A (for aerobes) and 7B (for anaerobes) plus a thioglycolate medium and (ii) BACTEC media 6A, 7B, and 8A (hypertonic). In study 1, clinically significant isolates were identified in 1,873 (13.9%) of 13,432 blood cultures with all three media. The thioglycolate medium revealed 143 (1.1%) organisms not recovered from the 6A and 7B media. In study 2, isolates were identified in 1,135 (12.9%) of 8,759 cultures with all three media; 104 (1.2%) organisms were isolated only from the hypertonic medium. The increased yield of positive cultures in the three-medium system is likely due to the larger volume of blood cultured.
منابع مشابه
Detection of bacteremia in patients receiving antimicrobial therapy: an evaluation of the antimicrobial removal device and 16B medium.
A total of 1097 blood specimens obtained from patients receiving antibacterial antimicrobial agents were processed by three blood culture systems: standard aerobic and anaerobic radiometric media, resin-containing radiometric medium (16B; Johnston Laboratories, Cockeysville, Md.), and aerobic and anaerobic radiometric media inoculated with blood processed in an Antimicrobial Removal Device (Mar...
متن کاملControlled evaluation of supplemented peptone and Bactec blood culture broths for the detection of bacteremia and fungemia.
Comparison of conventional blood culture media with newer formulations of Bactec media for radiometric detection are lacking. Therefore, we compared the yield and speed of detection of clinically important microorganisms with supplemented peptone broth (SPB) and Bactec aerobic (6B) and anaerobic (7C or 7D) broths in 7,627 blood samples from adult patients. Acridine orange stains from SPB, radio...
متن کاملClinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media.
The efficiency of the 10-ml Isolator (E. I. du Pont de Nemours & Co., Inc.) for recovery of pathogens from blood was compared with that of BACTEC 6B and 7C media (Johnston Laboratories) by using 4,195 cultures from 1,662 patients. During the first phase of the study, BACTEC bottles were inoculated with 3 ml of blood; in the second phase, bottles were inoculated with 5 ml. The objectives were to...
متن کاملRadiometric detection of bacteremia: requirement for terminal subcultures.
A radiometric procedure for rapid detection of bacteria in clinical blood specimens was utilized over a period of 1 year in this laboratory. Although in initial studies it was felt that all positive bacteremias would be detected by radiometric examination of cultures for 14CO2 evolution over a 7-day period, we found in the present study that a significant number of bacteria were not detected, e...
متن کاملAssessment of the BACTEC NR660 blood culture system for the detection of bacteremia in young children.
The sensitivity of the BACTEC NR660 blood culture system was assessed by using paired bottles of anaerobic (NR7A) and resin-containing aerobic (NR16A) media and conditions and organisms which simulated those found in pediatric practice. Corresponding media (7D and 16B) of the established BACTEC 460 radiometric method served as controls. The performances of the two systems were similar with 50 i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 20 4 شماره
صفحات -
تاریخ انتشار 1984