Nuclear Instruments and Methods in Physics Research A281 (1989) 469-479 469 North-Holland, Amsterdam CALIBRATION OF ELECTROMAGNETIC CALORIMETERS IN HIGH ENERGY EXPERIMENTS WITH ARADIO FREQUENCY QUADRUPOLE ACCELERATOR
نویسندگان
چکیده
A fast, effective calibration technique has been developed for future Superconducting Supercollider (SSC) calorimeters based upon the radiative capture of protons from a pulsed Radio Frequency Quadrupole (RFQ) accelerator in a fluoride target . The intense flux of low energy photons acts as a clean "pulse generator" calibration signal equivalent to 20 GeV or more . This calibration technique has been demonstrated with a bismuth germanate (BGO) detector array, as well as with several barium fluoride detector crystals, to provide a calibration accuracy of 0.5% within two minutes . The SSC calibration has resulted from the developement of this novel technique by Caltech over the past five years for the L3 BGO electromagnetic calorimeter, which uses a lithium target for the production of 17 .6 MeV low energy photons for the calibration source . Proven techniques have been developed to provide an in situ calibration for all 11000 BGO detector crystals, with an accuracy of 0.8% obtainable in 1-2 h. The result of the experimental test by using the AccSys RFQ accelerator is reported, as is the preliminary concept of a small storage ring that can be used to compress the output beam pulse from the RFQ accelerator into a target beam pulse of 100 ns or less.
منابع مشابه
North-Holland, Amsterdam CALIBRATION OF THE L3 BGO ELECTROMAGNETIC CALORIMETER WITH A RADIOFREQUENCY QUADRUPOLE ACCELERATOR
A new calibration technique based on radiative capture of protons from an RFQ accelerator in a lithium target, which makes use of the resultant high intensity flux of 17 .6 MeV photons, has been developed and tested . The technique is capable of calibrating the thousands of BGO crystals in the L3 electromagnetic calorimeter at once, with an absolute accuracy of better than 1 % in 1-2 h. Systema...
متن کاملPrecision calibration of electromagnetic calorimeters with a radio-frequency quadrupole accelerator
Over the last six years, Caltech and AccSys Technology, Inc . have developed fast calibration techniques by using a pulsed proton beam from a radio-frequency quadrupole (RFQ) accelerator. The RFQ beam bombards a lithium (Li) or calcium fluoride (CaF2) target permanently installed in an experiment . Radiative capture of the proton yields a flux of single 17 .6 MeV photons from a Li target or sho...
متن کاملEffect of Extremely Low Frequency Electromagnetic Field and/or GABAB Receptors on Foot Shock-induced Aggression in Rats
Introduction: The present study investigated the interactive effect of GABAB receptors and extremely low frequency electromagnetic field (ELF-EMF) on foot shock-induced aggression in rats. Methods: fifty adult male rats were randomly assigned into 10 groups. Groups 2, 4, 6, 8 and 10 were exposed to 50 Hz, 500 µT ELF-EMF for 30 days 8h per day while the remaining groups (1, 3, 5, 7 and 9) were...
متن کاملNuclear Instruments and Methods in Physics Research A285 (1989) 71-75 71 North-Holland, Amsterdam PROPOSAL FOR A RACE-TRACK MICROTRON WITH HIGH PEAK CURRENT
In order to obtain high gain m a free electron laser a high-quality electron beam with high peak current is required . It is well-known that a microtron is able to produce a high-quality beam having low etntttance and small energy spread (1%0). Because a circular nucrotron has a linuted high-current capability a race-track design is adopted for providing flexibility, better beam quality and of ...
متن کاملThe Effect of Field Size and Distance from the Field Center on Neutron Contamination in Medical Linear Accelerator
Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many param...
متن کامل