Comparison of simulated periodontal bone defect depth measured in digital radiographs in dedicated and non-dedicated software systems.

نویسندگان

  • G Scaf
  • C E Sakakura
  • P F D Kalil
  • J A N Dearo de Morais
  • L C M Loffredo
  • A Wenzel
چکیده

OBJECTIVES To compare simulated periodontal bone defect depth measured in digital radiographs with dedicated and non-dedicated software systems and to compare the depth measurements from each program with the measurements in dry mandibles. METHODS Forty periodontal bone defects were created at the proximal area of the first premolar in dry pig mandibles. Measurements of the defects were performed with a periodontal probe in the dry mandible. Periapical digital radiographs of the defects were recorded using the Schick sensor in a standardized exposure setting. All images were read using a Schick dedicated software system (CDR DICOM for Windows v.3.5), and three commonly available non-dedicated software systems (Vix Win 2000 v.1.2; Adobe Photoshop 7.0 and Image Tool 3.0). The defects were measured three times in each image and a consensus was reached among three examiners using the four software systems. The difference between the radiographic measurements was analysed using analysis of variance (ANOVA) and by comparing the measurements from each software system with the dry mandibles measurements using Student's t-test. RESULTS The mean values of the bone defects measured in the radiographs were 5.07 mm, 5.06 mm, 5.01 mm and 5.11 mm for CDR Digital Image and Communication in Medicine (DICOM) for Windows, Vix Win, Adobe Photoshop, and Image Tool, respectively, and 6.67 mm for the dry mandible. The means of the measurements performed in the four software systems were not significantly different, ANOVA (P = 0.958). A significant underestimation of defect depth was obtained when we compared the mean depths from each software system with the dry mandible measurements (t-test; P approximately equal to 0.000). CONCLUSIONS The periodontal bone defect measurements in dedicated and in three non-dedicated software systems were not significantly different, but they all underestimated the measurements when compared with the measurements obtained in the dry mandibles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی و مقایسه دقت رادیوگرافی های پانورامیک، پری اپیکال و بایت وینگ در تعیین میزان تحلیل استخوان آلوئول در پریودنتیت

Introduction: The height of the alveolar bone, is normally maintained by equilibrium between bone formation and bone resorption, but in periodontal disease more destruction or lack of bone formation will reduce the alveolar bone height. However the radiography is important in diagnosis, treatment plan and detection of quality and quantity of the alveolar bone although the type of radiography is...

متن کامل

Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

PURPOSE This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. MATERIALS AND METHODS Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Ima...

متن کامل

Simulated annealing and artificial immune system algorithms for cell formation with part family clustering

Cell formation problem (CFP) is one of the main problems in cellular manufacturing systems. Minimizing exceptional elements and voids is one of the common objectives in the CFP. The purpose of the present study is to propose a new model for cellular manufacturing systems to group parts and machines in dedicated cells using a part-machine incidence matrix to minimize the voids. After identifying...

متن کامل

Commissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran

Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...

متن کامل

بررسی مقایسه‌ای اثرEnamel Matrix Protein به تنهایی و همراه با پیوند استخوانی اتوژن در درمان ضایعات پریودنتال انسانی داخل استخوانی دو دیواره

Statement of Problem: Regenerative periodontal procedures are one mode of therapy that attempts to restore the lost supporting structures of the dentition around a previously diseased root surface.Purpose: The purpose of this study was comparison between Enamel matrix proteins (EMP) used alone or in combination with autogenous bone graft (ABG) in the treatment of human intrabony periodontal def...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dento maxillo facial radiology

دوره 35 6  شماره 

صفحات  -

تاریخ انتشار 2006