Blood oxygen flux estimation with a combined photoacoustic and high-frequency ultrasound microscopy system: a phantom study.
نویسندگان
چکیده
The metabolic rate of oxygen consumption, an important indicator of tissue metabolism, can be expressed as the change of net blood oxygen flux into and out of a tissue region per 100 g of tissue. In this work, we propose a photoacoustic and Doppler ultrasound method for imaging local blood oxygen flux of a single vessel. An imaging system for combined photoacoustic and high-frequency ultrasound microscopy is presented. This system uses a swept-scan 25-MHz ultrasound transducer with confocal dark-field laser illumination optics. A pulse-sequencer enables ultrasonic and laser pulses to be interlaced so that photoacoustic and Doppler ultrasound images are co-registered. Since the mean flow speed can be measured by color Doppler ultrasound, the vessel cross-sectional area can be measured by power Doppler or structural photoacoustic imaging, and multi-wavelength photoacoustic methods can be used to estimate oxygen saturation (sO(2)) and total concentration of haemoglobin (C(Hb)), all of the parameters necessary for oxygen flux estimation can be provided. The accuracy of the flow speed and sO(2) estimation has been investigated. In vitro sheep blood phantom experiments have been performed at different sO(2) levels and mean flow speeds. Blood oxygen flux has been estimated, and the uncertainty of the measurement has been quantified.
منابع مشابه
Photoacoustic and high-frequency power Doppler ultrasound biomicroscopy: a comparative study.
Both photoacoustic imaging and power Doppler ultrasound are capable of producing images of the vasculature of living subjects, however, the contrast mechanisms of the two modalities are very different. We present a quantitative and objective comparison of the two methods using phantom data, highlighting relative merits and shortcomings. An imaging system for combined photoacoustic and high-freq...
متن کاملEnhancement of Toxic Substances Clearance from Blood Equvalent Solution and Human Whole Blood through High Flux Dialyzer by 1 MHz Ultrasound
Background: Hemodialysis is a process of removing waste and excess fluid from blood when kidneys cannot function efficiently. It often involves diverting blood to the filter of the dialysis machin to be cleared of toxic substances. Fouling of pores in dialysis membrane caused by adhesion of plasma protein and other toxins will reduce the efficacy of the filtre.Objective: In This study, the infl...
متن کاملMultimodal simultaneous photoacoustic tomography, optical resolution microscopy and OCT system
A novel combined photoacoustic tomography (PAT), optical resolution photoacoustic microscopy (ORPAM) and optical coherence tomography (OCT) instrument has been developed for imaging biological tissues. The system is based on the use of a Fabry-Perot (FP) polymer film ultrasound sensor. This is designed to be transparent to wavelengths between 590nm and 1200nm so that photoacoustic excitation la...
متن کاملPhotoacoustic tissue characterization using envelope statistics and ultrasonic spectral parameters
Photoacoustic (PA) tissue characterization relies on the analysis of ultrasound (US) signals generated through the PA effect. The probability distributions of PA signal amplitude as well as the frequency content of the PA signals are typically not considered. We present a phantom study where we introduce the combined use of US/PA signal envelope statistics along with analysis of the frequency c...
متن کاملAbsolute measurements of local chromophore concentrations using pulsed photoacoustic spectroscopy
Photoacoustic spectroscopy has the potential to make non-invasive, spatially resolved measurements of absolute chromophore concentrations. This has a wide range of possible applications, for example the mapping of endogenous chromophores such as oxy(HbO2) and deoxyhaemoglobin (HHb) or externally administered contrast agents designed to target specific tissues or molecular processes. In this stu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 17 3 شماره
صفحات -
تاریخ انتشار 2012