Lactate and venoarterial carbon dioxide difference/arterial-venous oxygen difference ratio, but not central venous oxygen saturation, predict increase in oxygen consumption in fluid responders.

نویسندگان

  • Xavier Monnet
  • Florence Julien
  • Nora Ait-Hamou
  • Marie Lequoy
  • Clément Gosset
  • Mathieu Jozwiak
  • Romain Persichini
  • Nadia Anguel
  • Christian Richard
  • Jean-Louis Teboul
چکیده

OBJECTIVES During circulatory failure, the ultimate goal of treatments that increase cardiac output is to reduce tissue hypoxia. This can only occur if oxygen consumption depends on oxygen delivery. We compared the ability of central venous oxygen saturation and markers of anaerobic metabolism to predict whether a fluid-induced increase in oxygen delivery results in an increase in oxygen consumption. DESIGN Prospective study. SETTING ICU. PATIENTS Fifty-one patients with an acute circulatory failure (78% of septic origin). MEASUREMENTS Before and after a volume expansion (500 mL of saline), we measured cardiac index, o2- and Co2-derived variables and lactate. MAIN RESULTS Volume expansion increased cardiac index ≥ 15% in 49% of patients ("volume-responders"). Oxygen delivery significantly increased in these 25 patients (+32% ± 16%, p < 0.0001). An increase in oxygen consumption ≥ 15% concomitantly occurred in 56% of these 25 volume-responders (+38% ± 28%). Compared with the volume-responders in whom oxygen consumption did not increase, the volume-responders in whom oxygen consumption increased ≥ 15% were characterized by a higher lactate (2.3 ± 1.1 mmol/L vs. 5.5 ± 4.0 mmol/L, respectively) and a higher ratio of the veno-arterial carbon dioxide tension difference (P(v - a)Co2) over the arteriovenous oxygen content difference (C(a - v)o2). A fluid-induced increase in oxygen consumption greater than or equal to 15% was not predicted by baseline central venous oxygen saturation but by high baseline lactate and (P(v - a)Co2/C(a - v)o2 ratio (areas under the receiving operating characteristics curves: 0.68 ± 0.11, 0.94 ± 0.05, and 0.91 ± 0.06). In volume-nonresponders, volume expansion did not significantly change cardiac index, but the oxygen delivery decreased due to a hemodilution-induced decrease in hematocrit. CONCLUSIONS In volume-responders, unlike markers of anaerobic metabolism, central venous oxygen saturation did not allow the prediction of whether a fluid-induced increase in oxygen delivery would result in an increase in oxygen consumption. This suggests that along with indicators of volume-responsiveness, the indicators of anaerobic metabolism should be considered instead of central venous oxygen saturation for starting hemodynamic resuscitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ratios of central venous-to-arterial carbon dioxide content or tension to arteriovenous oxygen content are better markers of global anaerobic metabolism than lactate in septic shock patients

BACKGROUND To evaluate the ability of the central venous-to-arterial CO2 content and tension differences to arteriovenous oxygen content difference ratios (∆ContCO2/∆ContO2 and ∆PCO2/∆ContO2, respectively), blood lactate concentration, and central venous oxygen saturation (ScvO2) to detect the presence of global anaerobic metabolism through the increase in oxygen consumption (VO2) after an acut...

متن کامل

Central venous-to-arterial carbon dioxide difference combined with arterial-to-venous oxygen content difference is associated with lactate evolution in the hemodynamic resuscitation process in early septic shock

INTRODUCTION Since normal or high central venous oxygen saturation (ScvO₂) values cannot discriminate if tissue perfusion is adequate, integrating other markers of tissue hypoxia, such as central venous-to-arterial carbon dioxide difference (PcvaCO₂ gap) has been proposed. In the present study, we aimed to evaluate the ability of the PcvaCO₂ gap and the PcvaCO₂/arterial-venous oxygen content di...

متن کامل

End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning

Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...

متن کامل

Venoarterial carbon dioxide gradient utility as a criterion for blood transfusion at the intensive care unit

Methods Patients within their first 12 hours from admission to the intensive care unit (ICU) during the hemodynamic optimization protocol in which blood transfusion was decided to rise the Sv02 after hemodynamic optimization: central venous pressure (CVP)>8 mmHg, mean arterial pressure (MAP)>65 mmHg, peripheral oxygen saturation (Sp02) >90%. Pre and post transfusion hemoglobin, venous oxygen sa...

متن کامل

Repeatability of Blood Gas Parameters, Pco2 Gap, and Pco2 Gap to Arterial-to-Venous Oxygen Content Difference in Critically Ill Adult Patients

The objective of this study was to examine the repeatability of blood gas (BG) parameters and their derived variables such as the central venous-to-arterial carbon dioxide tension difference (▵PCO2) and the ratio of ▵PCO2 over the central arteriovenous oxygen content difference (▵PCO2/C(a-cv)O2) and to determine the smallest detectable changes in individual patients.A total of 192 patients with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 41 6  شماره 

صفحات  -

تاریخ انتشار 2013