Comparison of two methods using atomic absorption spectrometry for determination of selenium in food.

نویسندگان

  • M Matek
  • M Blanusa
  • J Grgić
چکیده

This study describes and compares two methods of atomic absorption spectrometry (AAS) for the selenium (Se) analysis in food: electrothermal AAS (ET AAS) and hydride generation method of AAS (HG AAS). The accuracy of the two methods was established by analysing two biological reference materials: Wheat Flour 1567a and Bovine Liver 1577b from the National Institute of Standards and Technology, USA. Good agreement with certified values was obtained for both methods. The accuracy of ET AAS method is 109% and 103% for Wheat Flour and Bovine Liver, respectively. The respective accuracies for HG AAS method were 88% and 87%. The detection limit obtained for ET AAS was 1 microgram Se/L and for HG AAS 0.02 microgram Se/L. The repeatability of ET AAS method was 5-11% and that of HG AAS 14-17%. Both methods are similar in accuracy and repeatability, but hydride generation (HG AAS) is more sensitive than graphite furnace technique (ET AAS) for determination of selenium in food.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry after Cloud Point Extraction

A new method for the determination of trace copper(II) in food samples by Cloud Point Extraction(CPE) combined with Flame Atomic Absorption Spectrometry(FAAS) is presented and evaluated. The method is based on the fact that hydrophobic complex of copper(II) with sodium diethyldithiocarbamate (DDTC) was formed at pH 6.0 and subsequently the hydrophobic complex was extracted into surfactant-r...

متن کامل

Comparison of Modified Palladium Nanoparticles and Homemade Activated Carbon Derived from Medlar for Solid Phase Extraction of Metal Ions Prior to Their Flame Atomic Absorption Spectrometry Determination

This study focus on the preparation of two supports including activated carbon derived from medlar and Palladium nanoparticles loaded on activated carbon (Pd-NP-AC). Subsequently, both adsorbent modified with a novel Schiff base chelating agent and their potential applicability for determination of trace amounts of metal ions from aqueous solution has been investigated. The method is based on c...

متن کامل

Ion Pair Dispersive Liquid-Liquid Microextraction for the Determination of Trace Amounts of Copper(II) in Soil, Multivitamin Tablet, Tea and Water Samples Using Flame Atomic Absorption Spectrometry

Ion pair dispersive liquid- liquid microextraction (IP-DLLME) method combined with flame atomic absorption spectrometry was proposed for the determination of trace amounts of copper(II). By using pyrocatechol violet as chelating agent and cetyltrimethyl ammonium bromide as an ion pairing agent, the trace amount of copper(II) was extracted in chloroform. The factors influencing the formation cop...

متن کامل

Determination of trace amounts of chromium ions in water and food samples using ligand-less solid phase extraction-based modified nano-boehmite(AlOOH)

Chromium is one of the hazardous pollutants in industrial effluents. In this study, a new nano-boehmite modified with sodium dodecyl sulphate is developed for preconcentration trace amounts of chromium ions as a prior step to its determination by flame atomic absorption spectrometry. We investigated the effect of various parameters on the recovery of the analyte ions, including pH of sample solut...

متن کامل

Determination of Total Selenium in Infant Formulas: Comparison of the Performance of FIA and MCFA Flow Systems

Two flow methods, based, respectively, on flow-injection analysis (FIA) and on multicommutated flow analysis (MCFA), were compared with regard to their use for the determination of total selenium in infant formulas by hydride-generation atomic absorption spectrometry. The method based on multicommutation provided lower detection and quantification limits (0.08 and 0.27 μg L(-1) compared to 0.59...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arhiv za higijenu rada i toksikologiju

دوره 50 3  شماره 

صفحات  -

تاریخ انتشار 1999