Increasing isoflurane concentration may cause paradoxical increases in the EEG bispectral index in surgical patients.
نویسندگان
چکیده
We have studied the effects of increases in isoflurane concentration on the EEG bispectral index (BIS) in 70 patients anaesthetized with isoflurane-nitrous oxide-sufentanil for major abdominal surgery. During surgery, baseline BIS was recorded at 0.8% end-tidal isoflurane with nitrous oxide in oxygen (FIO2 0.35). After this, end-tidal isoflurane was increased to 1.6% for 15 min and decreased subsequently to 0.8% for 20 min to assess recovery. In 20 patients, BIS decreased from a mean value of 40 (SD 9) during baseline to 25 (10) at 1.6% isoflurane. In contrast, BIS did not change in 23 patients and increased in 27 patients from 35 (6) to 46 (8) as isoflurane was increased to 1.6%. In all patients, BIS recovered to baseline values at 0.8% isoflurane. The changes in BIS with increasing isoflurane concentration were not related to drugs or differences in physiological variables, which did not differ between groups. Patients with a decrease in BIS were significantly younger (38 (range 18-68) yr) than those with unchanged (55 (26-70) yr) or increased (60 (40-70) yr) BIS values (P < 0.001). It is possible that the paradoxical increase in BIS is related to continuous pre-burst EEG patterns consisting of high-frequency activity. This suggests that the use of BIS as a guide for isoflurane administration may be misleading in some patients undergoing surgical procedures.
منابع مشابه
Paradoxical changes in bispectral index during nitrous oxide administration.
I report two patients undergoing open heart surgery, with nitrous oxide and isoflurane anaesthesia, for whom bispectral index (BIS) monitoring showed high BIS values with nitrous oxide and isoflurane anaesthesia. The BIS decreased immediately after nitrous oxide was stopped and increased again after nitrous oxide was restarted.
متن کاملEvaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index
Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic techn...
متن کاملBispectral index in pediatrics: fashion or a new tool?
The bispectral index (BIS, Aspect Medical Systems, Inc. Newton, MA) is becoming the gold standard for assessing depth of anesthesia in adult patients. Indeed, BIS values are highly correlated with the concentration of hypnotic drugs such as propofol or sevoflurane (1–8). The BIS is derived from a large database of EEG traces obtained in adult patients under various conditions of anesthesia (9)....
متن کاملThe bispectral index system in pediatrics--is it related to the end-tidal concentration of inhalation anesthetics?
UNLABELLED BACKGROUND AND GOAL OF STUDY: Bispectral Index (BIS) has been used in adults to measure depth of anesthesia using various protocols. Though less investigated in children, there is growing evidence that bispectral index seems adequately calibrated for monitoring the depth of isoflurane and sevoflurane anesthesia in pediatric patients. A range of BIS scores (40-60) has been seen to be ...
متن کاملمزایای مانیتورینگ Bispecteral index در افراد چاق کاندید کولهسیستکتومی لاپاراسکوپیک در بیهوشی با ایزوفلوران
Background: Morbid obesity is associated with a some of significant comorbidities. Early and uneventful postoperative recovery of obese patients remains a challenge for anesthesiologists. It seems Bispecteral Index (BIS) monitoring may reduce drug usage and hasten recovery time in inhalation anesthesia. The aim of this study was to investigate the effect of BIS monitoring on intraoperative isof...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 85 1 شماره
صفحات -
تاریخ انتشار 2000